D60 GC Generator Set

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Generator Set Specifications

Minimum Rating
60 ekW
Maximum Rating
60 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
269in
Compression Ratio
16.7:1
Aspiration
Turbocharged
Fuel System
Electronic (adjustable)
Governor Type
Mechanical, ADEM™A4

Generator Set Dimensions

Length - Maximum
77.2in
Width - Maximum
43.3in
Height - Maximum
48in
Dry Weight - Genset (maximum)
2054lb

Standard/Optional Features

Standard Equipment:

  • Certificates
    • IBC Seismic and Wind Certifications
  • Air Inlet System
    • Air Cleaner
    • Cartridge type air filter
  • Circuit Breakers
    • Second circuit breaker box
    • Breakers (100% UL rated)
    • 3-Pole 100% rated
    • Power perminal strips
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Control Panel
    • GCCP 1.2 Control panel
  • Control Panels
    • NFPA110 bundle includes:
    • WSS1 Low coolant level shut down
    • FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected
    • WCA1 Low coolant temperature alarm
    • A coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
    • Oil temperature guage and sender
    • PBC10NU NFPA Battery Charger
    • PAA1 Panel mounted audible alarm
    • Remote E-stop button
    • Audible alarm
    • Ground fault relay
    • Remote annunciator
    • Volt free contacts genset run and common alarm
    • Discrete I/O module
    • Overload shutdown via breaker
    • Low coolant temperature alarm
    • Fuel level reading
    • Low coolant level shutdown
    • Protective devices:
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
  • Cooling System
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Radiator and cooling fan with guards
    • Caterpillar extended life coolant
    • Radiator stone guard
  • Generator
    • 12 leads
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
  • General
    • Engine and alternator pre-paint, Caterpillar Yellow
  • Starting/charging System
    • 24V battery with rack and cables
    • Batteries

Optional Equipment:

  • Certificates
    • IBC Seismic and Wind Certifications
  • Alternator System
    • R frame auxilliary winding
  • Air Inlet System
    • Cartridge type air filter
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Circuit Breakers
    • 3-Pole 100% rated
    • Breakers (100% UL rated)
    • Power perminal strips
    • Second circuit breaker box
  • Control Panels
    • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
    • NFPA110 bundle includes: FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low Coolant level shut down - WCA1 Low Coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA Battery Charger - A coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
    • Oil temperature guage and sender
    • Volt free contacts genset run and common alarm
    • Discrete I/O module
    • Remote annunciator
    • Remote E-stop button
    • Ground fault relay
    • Audible alarm
  • Cooling System
    • Radiator transition flange
    • Radiator transition flange
  • Enclosures
    • External emergency stop
    • Sound attenuated enclosure, level 1
    • Panel viewing window
    • Sound attenuated enclosure, level 2
  • Heating Elements
    • Battery heater
    • Wiring for canopy space heater
    • Jacket water heater
    • Lube oil sump heater
    • Anti-condensation heater
    • Coolant heater
    • Wiring for canopy space heater
    • Lube oil sump heater
    • Coolant heater
    • Battery heater
    • Anti-condensation heater
    • Jacket water heater
  • Exhaust System
    • 10, 25 and 35 dBA silencer systems
    • Overhaed silencer mounting kit
    • 10, 25 and 35 dBA silencer systems
    • Overhaed silencer mounting kit
  • Fuel System
    • Tank riser
    • Emergency vent pipe
    • 5 gallon spill containment
    • 209 and 394 gallon sub-base fuel tanks
    • 5 gallon fill containment
    • Tank riser
    • 5 gallon fill containment
    • 5 gallon spill containment
    • 209 and 394 gallon sub-base fuel tanks
    • Emergency vent pipe
  • Generators
    • Permanent magnet generator
    • Permanent magnet generator
  • Mounting System
    • Seismic vibration isolators
    • Seismic vibration isolators
  • Tests
    • 4 Hour factory test
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Generator test report
    • 4 Hour factory test
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Generator test report

See how D60 GC compares against frequently compared products

D60 GC

Selected Model

Compare with other Cat Models

Compare Now

Media Gallery

Check out our current offers

View Specials