3516E Low Voltage Generator Set

Diesel Generator Sets
Diesel Generator Sets (181)

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50�C (122�F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • CSA
  • IBC seismic certification
  • OSHPD pre-approval
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50�C (122�F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • CSA
  • IBC seismic certification
  • OSHPD pre-approval
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Engine Specifications

Bore
6.69in
Stroke (HD)
8.46in
Aspiration
ATAAC
Fuel System
MEUI
Engine Model
3516E, V-16, 4-Stroke, Water-Cooled Diesel
Compression Ratio
13.9:1 / 14.3:1
Governor Type
Adem™ A5
Aspiration
ATAAC
Fuel System
MEUI
Bore
6.69in
Stroke - HD
8.46in
Displacement
4765in³
Stroke
8.47in

Generator Set Specifications

Minimum Rating
2725 ekW
Maximum Rating
3000 ekW
Voltage
416 to 13,800 Volts
Frequency
60 Hz
Speed
1800 rpm
Emissions/Fuel Strategy
Tier 2
Height - Maximum
103.9in
Duty Cycle
Standby, Mission Critical, Prime
Standby Rating
3000 ekW
Prime Power Rating
2725 ekW

Generator Set Dimensions

Height - Maximum
143in
Length - Maximum
304in
Width - Maximum
113in
Dry Weight - Genset (maximum)
44930lb

Standard/Optional Features

Standard Equipment:

  • Air Inlet System
    • Single element canister type with service indicator
    • Air cleaner
  • Cooling
    • Package mounted radiator
  • Exhaust
    • Exhaust flange outlet
  • Fuel
    • Primary fuel filter with integral water separator
    • Fuel priming pump
  • Generator
    • IP23 Protection
    • Matched to the performance and output characteristics of Cat engines
  • Power Termination
    • Busbar
  • Starting/charging
    • Heavy duty starting system
    • Charging alternator
  • Control Panel
    • Over/under voltage (27/59)
    • Emergency stop pushbutton
    • Speed adjust
    • Accessory module data link
    • Generator phase sequence
    • Panel lights
    • Alarm acknowledge
    • Generator mounted - rear facing
    • kW (per phase, average & percent)
    • Engine cool-down timer
    • Communications:
    • High coolant temperature
    • Warning/shutdown with common LED indication of shutdowns for:
    • Overcurrent (50/51)
    • Amps (per phase & average)
    • Oil pressure (psi, kPa or bar)
    • Serial annunciator module data link
    • 24 Volt DC operation
    • Cat ECS controller includes:
    • DC volts
    • Reverse reactive power (kVAr) (32RV)
    • 6 Programmable digital inputs
    • 2 Programmable relay outputs (Form C)
    • Frequency (Hz)
    • Customer data link (Modbus RTU)
    • Power factor (per phase & average)
    • kW-hr (total)
    • Cat ECS 100
    • Lamp test
    • kVA (per phase, average & percent)
    • kVAr-hr (total)
    • Coolant temperature
    • Text alarm/event descriptions
    • Over/under frequency (81 o/u)
    • kVAr (per phase, average & percent)
    • 4 Programmable relay outputs (Form A)
    • Low coolant level
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Failure to start (overcrank)
    • Operating hours
    • Low coolant temperature
    • 2 Programmable digital outputs
    • Low oil pressure
    • Controls:
    • Digital indication for:
    • Environmental sealed front face
    • Overspeed
    • Volts (L-L & L-N)
    • Reverse power (kW) (32)
    • Engine cycle crank
    • Programmable protective relaying functions:
  • Cooling System
    • Fan and belt guards
    • JWAC
    • Radiator fan and fan drive
    • Coolant level sensors
    • Caterpillar extended life coolant
    • Coolant drain line with valve
  • Exhaust System
    • Flanged faced outlet(s)
    • Dry exhaust manifold
  • Fuel System
    • Fuel cooler; not included with packages without radiator
    • Fuel priming pump
    • Secondary fuel filters
    • Flexible fuel lines - shipped loose
  • Generators And Attachments
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
    • NEMA standard hole pattern
    • Anti-condensation space heater
    • Permanent magnet excitation (PMG)
    • Form wound
    • 3 Phase brushless, Salient pole
    • 6 Lead
    • Winding temperature detectors
    • Right side extension terminal box, busbar connections, top mounted, bottom cable entry
  • Governing System
    • ADEM III
  • Literature
    • Parts book
  • Lube System
    • Gear type lube oil pump
    • Integral lube Oil cooler
    • Fumes disposal
    • Oil drain lines and valve
    • Oil filter, filler and dipstick
    • Lubricating oil
  • Mounting System
    • Rubber anti-vibration mounts - shipped loose
    • Rails - engine/generator/radiator mounting
  • Starting / Charging System
    • 45 Amp Charging alternator
    • Battery and battery rack w/cables
    • Battery disconnect switch
    • 24 Volt electric starting motor
  • General
    • Right hand servicing
    • Paint - Caterpillar yellow with high gloss black rails & radiator
    • SAE standard rotation
    • Flywheel and flywheel housing-SAE No. 00

Optional Equipment:

  • Air Inlet System
    • Air inlet protection
    • Remote air inlet adapters
    • Heavy duty air cleaners
    • Dual element air cleaners
  • Circuit Breakers
    • 2000, 2500, 3200, 4000 Amp, 4 Pole, IEC rated Circuit breakers
    • Circuit breaker harnesses
    • Masterpact breaker connections
    • P Frame breaker connections
    • 2000, 2500, 3200, 4000, 5000 Amp, 3 Pole, IEC rated Circuit breakers
    • Busbar connections
    • R Frame breaker connections
    • Cable entry options
    • 1600, 2000, 2500, 3000, 4000, 5000 Amp, 3 Pole, UL-100% rated Circuit breakers
    • Optional busbar power connections
  • Power Termination
    • Circuit breakers, IEC compliant
  • Control Panel
    • Voltage raise/lower switch
    • PC monitoring (Remote and local)
    • Generator temperature monitoring
    • Remote speed adjust
    • Annunciator modules
    • EMCP 4.4
    • Vandal proof panel door
    • Auxiliary box
    • Customer interface options
    • Ground
    • Language options
    • Load share module options
    • Mounting group - External box clips
  • Cooling System
    • Optional Serpentine radiators
    • Optional ATAAC radiators
    • Water level switch gauges
    • Expansion tanks
  • Exhaust System
    • Flexible fittings
    • Y Adapters
    • Elbows
    • Mufflers
    • Flanges
    • Flanges and exhaust fittings
  • Fuel System
    • Duplex fuel filters
    • Primary fuel filters
  • Generators And Attachments
    • Differential current transformers - 8.7 and 15 kV class
    • Alternator air cleaners
  • Instrumentation
    • Pyrometer and thermocouples
  • Lube System
    • Manual prelube pump
    • Electric prelube pumps
    • Oil level regulator
    • Lube oil in standard sump
  • Mounting System
    • Spring type vibration isolators
    • IBC Seismic vibration isolators NORAD
    • Puck style low efficiency lsolators
  • Power Connections
    • Neutral ground connections
    • 2700 & 3000 Frame
    • Grounding groups
  • Special Tests / Reports
    • Fuel consumption test
    • Torsional vibration analysis
    • Standard engine test charge
    • IBC Certifications
    • Generator set consumption test
    • Generator set test report
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • Engine barring group
    • 10, 20, 35 and 50 Amp Battery chargers
    • Starter cover
    • Jacket water heaters
    • 24 Volt battery set - Dry
    • Electric starting motors
    • Air starting motors
    • Air pressure regulator
  • General
    • US aid emblem
    • Special paint colors

Take The Virtual Product Tour To Explore The Features And Benefits of the 3516E Low Voltage Generator Set

See how 3516E (60 Hz) compares against frequently compared products

3516E (60 Hz) Diesel Generator Sets

Engine Model
3516E, V-16, 4-Stroke, Water-Cooled Diesel
Voltage
416 to 13,800 Volts
Maximum Rating
3000 ekW
Selected Model

C1.5 (50 Hz) Diesel Generator Sets

Engine Model
Cat® C1.5
Voltage
110 to 415 Volts
Maximum Rating
13.5 kVA
View Full Specs

C1.1 (50 Hz) Diesel Generator Sets

Engine Model
C1.1, In-line 4 4-cycle diesel
Voltage
110 to 415 Volts
Maximum Rating
9.5 kVA
View Full Specs

Compare with other Cat Models

Compare Now

Media Gallery

Check out our current offers

View Specials
Translate »