C175-16 Tier 4 Final

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Request a Quote
Bore
8.89 in
Displacement
5155.88 in³
Stroke
8.66 in
Compression Ratio 50 Hz
16:7:1

Product Specs

Engine Specifications

Bore
8.89in
Displacement
5155.88in³
Stroke
8.66in
Compression Ratio 50 Hz
16:7:1
Compression Ratio 60 Hz
15:3:1
Aspiration
Turbo Aftercooled
Fuel System
Common Rail
Engine Model
C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Governor Type
ADEM™ A4
Compression Ratio 50 Hz
16:7:1
Compression Ratio 60 Hz
15:3:1
Aspiration
Turbo Aftercooled
Fuel System
Common Rail
Bore
8.89in
Displacement
5155.88in³
Stroke
8.66in

Generator Set Specifications

Minimum Rating
2500 ekW
Maximum Rating
3100 ekW
Voltage
480 - 13800 Volts
Frequency
60 Hz
Speed
1800 RPM

Generator Set Configurations

Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Stationary Genset

Standard/Optional Features

Standard Equipment:

  • Air Inlet System
    • Air Cleaner; 4 x single element canister with service indicator(s).
  • Control Panel
    • EMCP4.3 controls including emergency stop button
    • EMCP4.3 controller including:
    • - 24-volt DC operation.
    • - Environmental sealed front face
    • - Text alarm/event descriptions
    • - Warning/shutdown with common LED indication of shutdowns with indicating lights for:
    • - Low oil pressure
    • - High coolant temperature.
    • - Overspeed
    • - Emergency stop.
    • - Failure to start (overcrank)
    • - Low coolant level (requires optional coolant sensor)
    • Generator mounted - rear facing.
    • Controls:
    • - Speed adjust
    • - Auto/start/stop control.
    • - Engine cool-down timer
    • - Engine cycle crank
    • - Alarm acknowledge
    • - Lamp test
    • - True RMS AC metering, 3-phase, +/-0.25% accuracy
    • Digital indication for:
    • - RPM
    • - DC volts
    • - Operating hours
    • - Coolant temperature
    • - Volts (L-L & L-N
    • - Frequency (Hz).
    • - Amps (per phase & average).
    • - Power Factor (per phase & average)
    • - kW (per phase, average & percent)
    • - kVA (per phase, average & percent)
    • - kVAr (per phase, average & percent)
    • - kW-hr (total)
    • - kVAr-hr (total)
    • Warning/shutdown with common LED indication of shutdowns for:
    • - Low oil pressure
    • - High coolant temperature
    • - Overspeed
    • - Emergency stop
    • - Failure to start (overcrank)
    • - Low coolant temperature
    • - Low coolant level
    • Programmable protective relaying functions:
    • - Generator phase sequence
    • - Over / Under voltage (27/59)
    • - Over / Under frequency (81 o/u)
    • - Reverse power (kW) (32)
    • - Reverse reactive power (kVAr) (32RV)
    • - Overcurrent (50/51)
    • Communications:
    • - Customer data link (Modbus RTU)
    • - Accessory module data link
    • - Serial annunciator module data link
    • - 6 programmable digital inputs
    • - 4 programmable relay outputs (Form A
    • - 2 programmable relay outputs (Form C)
    • - 2 programmable digital outputs
    • - 12 programmable digital inputs
    • - 16 programmable digital outputs
    • - 3 programmable analog inputs
    • - 3 programmable analog outputs
    • - 2 programmable PWM outputs
    • Local annunciator option
  • Cooling System
    • SCAC cooling
    • Radiator group shipped loose.
    • Fan and belt guards
    • Coolant drain line and valves
    • Coolant sensor - (2 x shipped loose: 1/4-18 and 1/2-14 NPTF).
  • Exhaust System
    • Insulated CEM
    • CEM dosing module
    • CEM dosing module features:
    • - Air filter
    • - DEF filter
    • - 120VAC
    • - Freeze protection
    • - DEF line purge
    • - External relay
    • Harness from dosing module to CEM
    • Air and heated DEF lines from dosing module to CEM
    • Dry exhaust manifold
    • Flanged faced outlets at CEM in (21.2") and out (25")
  • Fuel System
    • Primary fuel filter water / fuel water separator
    • 10 Micron spin on type
    • 3 Filters, shipped loose - can be mounted on frame rails (Requires dealer provided flex)
    • Secondary / tertiary fuel filters
    • 4 Micron Spin On Type
    • 3 Filters, engine mounted
  • Generator And Attachments
    • 3 Phase brushless, salient pole
    • 6 lead
    • IEC platinum stator RTDs (.00385 temperature coefficient)
    • Caterpillar's digital voltage regulator (CDVR) includes:
    • - Reactive droop capability
    • - 3-Phase voltage sensing
    • - KVAR / PF modes
    • - RFI suppression
    • - Min / Max exciter limiter
    • - Exciter diode monitor
    • 1800 Frame generators (LV/MV)
    • Form wound
    • NEMA Class H insulation
    • Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • (LV) Bus bar connections, top / center mounted, top cable entry
    • - 60 Hz models: NEMA standard hole pattern
    • (MV)Bus bar connections, right side extension box, bottom cable entry
    • - 60 Hz models: NEMA standard hole pattern.
    • 3000 Frame generators (MV/HV)
    • Form wound
    • Permanent magnet
    • Anti condensation space heater
    • NEMA Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
    • Right side extension box, bottom cable entry
  • Governing System
    • ADEM A4
    • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
  • Lube System
    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
    • Prelube - required with prime and continuous; optional with standby
  • Mounting System
    • Rails - Engine / Generator
    • Rubber anti-vibration mounts (shipped loose).
    • Dual 24-volt electric starting motors
    • Batteries and battery rack w/cables
    • Battery disconnect switch
  • Service Instructions
    • Two PM Inspections
  • General
    • Paint - Caterpillar yellow with high gloss black rails & radiator
    • RH Service (except oil filter service 60 Hz models: left hand service
    • Flywheel and flywheel housing-SAE No. 00
    • SAE standard rotation
    • *For HV EMCP4.3 control panel: Includes wall mount control panel, shipped loose, for customer mounting and 7.5 meter interconnect harness.
    • * For HV applications, customer to provide 120V secondary sensing, 5A secondary current sensing and harness between package and EMCP4.3 (drawing provided). CDVR is installed in wall mount.

Optional Equipment:

  • Air Inlet System
    • Single stage air cleaner
  • Control Panels
    • EMCP 4.3
    • EMCP 4.4 requires 1800 frame low voltage packages
    • E-Stop - Only for use with 3000 frame generators and EMCP4.3
    • Load share module
    • EMCP mounting location - LV / MV -- requires 1800 frame generator
    • Customer AC-DC connection mounting location - LV / MV
    • Load share governor / auxiliary plate and auxiliary box (LV)
    • Remote speed adjust
    • Annunciator modules
    • Customer interface options
    • Generator temperature monitoring
    • Modbus monitoring of packages
    • Vandal proof panel door
  • Cooling System
    • Package mounted radiator
    • Remote radiators
    • SCAC circuits
    • Fuel cooler
  • Exhaust
    • Exhaust collectors / manifold
  • Fuel System
    • Primary fuel filter
  • General
    • Paint - colors (other than Caterpillar yellow) or high performance paints
    • US aid emblem
  • Generator And Attachments
    • 480 Volts, Generators (LV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 - 1800 frame
    • 480 Volts, Generators (MV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 -- 1800, 3000 frame
    • Space heater kit
    • Thermostat for space heater
    • Differential current transformers (DCT):
    • - 5, 9 and 15 kV class DCTs
  • Instrumentation
    • Pyrometer and thermocouples
    • Harness - ECM interconnect
  • Lube System
    • Lube oil heater
    • Oil pan drain valve
    • Standard sump oil pan
    • Lubricating oil
    • Electric prelube pump
    • Oil filters
  • Crankcase Systems
    • Explosion relief valves
  • Mounting System
    • Rubber anti-vibration mounts
    • Spring-type linear vibration isolators
    • IBC vibration isolators - shipped loose
  • Power Connections
    • Center post busbars (LV) connections
    • Side / Rear monted busbars (LV)
    • Cable entry options (LV)
    • Control packating (LV) - Enclosures
    • Power connection covers
    • Optional package mounted circuit breakers (LV)
    • 4000 Amp, 3 Pole, UL-100% Rated Circuit Breakers
    • 4000 Amp, 3 Pole, IEC-Rated Circuit Breakers
    • 5000 Amp, 3 Pole, UL-100% Rated Circuit Breakers
    • 5000 Amp, 3 Pole, IEC-Rated Circuit Breakers
    • Circuit Breaker Harness
    • MV Power Connection Options:
    • - 1800 Frame generator side / rear mounted busbars:
    • - Left hand MV nema busbar
    • - Right hand MV nema busbar
    • Cable entry options - 1800 frame (MV)
    • Neutral ground - (MV)
    • Masterpack breaker connections
  • Service Tools - Barring Groups
    • Engine group
    • Group manual
    • Engine air powered
    • Control GP-airpowered group
  • Special Tests / Reports
    • Generator test report
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard genset torsional nibration analysis (TVA) report
    • Custom genset TVA report
    • Fuel consumption test
    • Standard engine test charge
  • Starting/charging
    • 24 Volt power distribution box
    • 24 Volt electric starting motor
    • Air starting motor
    • Covers - starter locations
    • 24 Volt battery set - dry
    • Heavy duty battery set with rack
    • 35 and 50 Amp battery chargers
    • Jacket water heaters
    • Jacket water heater wiring groups