C32 (60 Hz)

Diesel Generator Sets
Diesel Generator Sets (181)

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • CSA
  • IBC seismic certification
  • OSHPD pre-approval
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • CSA
  • IBC seismic certification
  • OSHPD pre-approval
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Engine Specifications

Bore
5.71in
Displacement
1958.86in³
Stroke
6.38in
Aspiration
TA
Fuel System
MEUI
Engine Model
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Compression Ratio
15.0:1
Governor Type
Adem™A4
Aspiration
TA
Fuel System
MEUI
Bore
5.71in
Displacement
1958.86in³
Stroke
6.38in
Fuel System
6.38in

Generator Set Specifications

Minimum Rating
830 ekW
Maximum Rating
1250 ekW
Voltage
220 to 4160 Volts
Frequency
60 Hz
Speed
1800 rpm
Emissions/Fuel Strategy
Low Fuel, Tier 2 Nonroad Stds
Duty Cycle
Standby, Mission Critical, Prime, Continuous

Generator Set Dimensions

Height - Maximum
86.4in
Length - Maximum
172.7in
Width - Maximum
87.7in
Length - Minimum
164in
Width - Minimum
66.3in
Height - Minimum
85.1in
Dry Weight - Genset (minimum)
14700lb
Dry Weight - Genset (maximum)
16755lb

Standard/Optional Features

Standard Equipment:

  • Air Inlet System
    • Single element canister type with service indicator
  • Control Panel
    • Warning shutdowns
    • EMCP 4.2B
    • Digital Indicators
    • Communications
    • Control features
    • Programmable protective relaying functions
  • Cooling System
    • Caterpillar extended life coolant
    • ATAAC
    • Coolant drain line with valve
    • Low coolant level sensor
    • Fan and belt guards
    • Radiator fan and fan drive
  • Exhaust System
    • 203 mm (8 in) ID round flanged outlet
    • Exhaust manifold - dry
  • Fuel System
    • Fuel cooler
    • Fuel priming pump
    • Secondary fuel filters
    • Primary fuel filter with water separator
  • General
    • RH service
    • Caterpillar yellow with high gloss black rails & radiator
    • SAE standard rotation
    • Flywheel and flywheel housing-SAE
  • Generators And Attachments
    • Class H temperature rise at 40C ambient
    • 3 Phase brushless
    • Permanent magnet excitation (PMG)
    • Winding temperature detectors
    • Integrated voltage regulator (IVR)
    • Reactive droop
    • IEC standard hole pattern
    • NEMA Class H insulation
    • Busbar connections, top center mounted, top cable entry
    • Salient pole
    • 6 Lead
    • Internal excitation (IE)
  • Governing System
    • ADEM(tm) A4
  • Lube System
    • Gear type lube oil pump
    • Oil drain lines and valve
    • Fumes disposal
    • Lubricating oil
    • Integral lube Oil cooler
    • Oil filter, filler and dipstick
  • Mounting System
    • Rubber anti-vibration mounts
    • Rails - Engine/generator/radiator mounting
  • Power Termination
    • Busbar
  • Starting And Charging
    • 45 Amp Charging alternator
    • 24 Volt electric starting motor
    • Battery disconnect switch
    • Battery, rack and cables

Optional Equipment:

  • Air Inlet System
    • Standard air cleaners
    • Heavy duty air cleaner
    • Dual element air cleaner
  • Circuit Breakers
    • Shrouds
    • 1600, 2000, 2500 and 3200 Amp, 3 Pole, IEC-Rated Circuit breakers
    • Center posts busbars
    • Enclosures - Control packaging
    • 400, 800, 1200, 1600, 2000, 2500 and 3000 Amp, 3 Pole, UL-100% Rated Circuit breakers
    • Circuit breaker wiring groups
    • Power connection covers
    • Cable supports
    • 800, 1600, 2000, 2500 and 3200 Amp, 4 Pole, IEC rated Circuit breakers
  • Control Panels
    • EMCP 4.3, EMCP 4.4
  • Cooling System
    • High ambient radiator
    • Extended life coolant
    • Standard radiator
    • Radiator duct flange
    • Certified radiator
  • Enclosures
    • Premium sound attenuated enclosure
    • Cold weather bundle
    • Color options
    • DC lighting package
    • Sound attenuated enclosure
    • AC Panel, outlets and lights
    • Panel bracket
    • Enclosure fuel tank options
    • Enclosure louvers - fixed and motorized
  • Exhaust System
    • Elbow mounting kit
    • Mufflers
    • Guard and shield system
    • Flange and exhaust expanders
    • Flexible fittings
    • All C32 engines have 203 mm (8 in) exhaust outlets
    • Flanges
    • Exhaust through the wall kit
  • General
    • US aid emblem
    • Special paint
  • Generator And Attachments
    • Medium voltage optional generators
    • Low voltage optional generators
  • Lube System
    • Oil level regulator
    • Oil pan
    • Prelube manual sump pump
  • Mounting System
    • Spring type vibration isolators
    • IBC vibration isolators
    • Mounting base types
    • Standard package isolators
  • Power Connections
    • Center post busbars
    • Low voltage connection cables
    • Neutral grounding connection
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Special Tests / Reports
    • Standard engine test
    • IBC seismic Certifications
    • PGS Test report @ 1.0 power factor
    • Custom generator TVA report
    • Generator test report
    • Standard genset Torsional Vibration Analysis (TVA) report
    • PGS Test report @ 0.8 power factor
    • CSA test and certification
    • OSHPD seismic Certifications
  • Starting / Charging
    • 10 Amp enclosure Battery charger
    • 35 Amp Battery charger
    • Space heater
    • Jacket water heater
    • Electric starting motor - Standard/heavy duty
    • Heavy duty starting system
    • 10 Amp Battery charger
    • 20 Amp Battery charger

Take The Virtual Product Tour To Explore The Features And Benefits of the C32 (60 Hz)

See how C32 (60 Hz) compares against frequently compared products

C32 (60 Hz) Diesel Generator Sets

Engine Model
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Voltage
220 to 4160 Volts
Maximum Rating
1250 ekW
Selected Model

C1.1 (60 Hz) Diesel Generator Sets

Engine Model
C1.1, In-line 4, 4-cycle diesel
Voltage
110 to 480 Volts
Maximum Rating
8.8 ekW
View Full Specs

C1.5 (60 Hz) Diesel Generator Sets

Engine Model
Cat® C1.5
Voltage
110 to 415 Volts
Maximum Rating
13.2 ekW
View Full Specs

Compare with other Cat Models

Compare Now

Media Gallery

Check out our current offers

View Specials
Translate »