Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Take Virtual Tour

Sorry, there aren’t current any videos for this product.

Sorry, there aren’t current any deals for this product.

https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-3ea27-3a140

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-da108-96542

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-92f47-79cda

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-30ae2-ee87d

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-0d295-12b36

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-71514-a5220

  • UL 2200 Listed
  • ULC Certification Available
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-0978e-242c4

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-90e57-21189

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Maximum Rating
100 ekW
Minimum Rating
100 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
269in³
Compression Ratio
16.7:1
Aspiration
Turbocharged
Fuel System
Common Rail
Governor Type
Mechanical, ADEM™A4
Length – Maximum
82.6in
Width – Maximum
43.3in
Height – Maximum
52.9in
Dry Weight – Genset (maximum)
2222lb
  • Air Inlet System
    • Air cleaner; light duty with disposable element
    • Air cleaner
  • Cooling System
    • Coolant drain line with valve
    • Radiator and cooling fan with guards
    • Caterpillar extended life coolant
    • Fan drive, battery charging alternator drive
  • Control Panel
    • GCCP 1.2 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use – shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
  • Generator
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • IP23 Protection
    • Tower panel, IP22, bottom cable entry
    • 12 Leads
    • Voltage regulator (single phase sensing)
    • Segregated low voltage (AC/DC) wiring panel
  • Governing System
    • Mechanical and electrical governing system – model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Termination points for coolant and lube oil drain lines
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provision and drag points
  • Starting/charging System
    • Batteries
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Alternator System
    • Anti-condensation heater
    • 3 phase sensing
    • Permanent magnet excitation (PMG)
    • R Frame auxilliary winding
    • Quadrature droop kit
  • Circuit Breakers
    • Circuit breaker upgrades – 4 Pole circuit reaker to 250A, 400A and 630 A
  • Cooling System
    • Coolant heater
    • Low coolant temperature alarm
    • Low coolant level shutdown
  • Control Panel Options
    • Earth fault (2 wire only)
    • Control panel heater
    • GCCP 1.2 Control panel
    • Volt free contacts
    • Emergency stop with key
    • Voltage adjust potentiometer
    • Overload shutdown via breaker
    • Panel mounted audible alarm
    • Battery charger
    • Earth leakage (2 wire only)
    • Speed adjust potentiometer
  • Enclosures
    • Sound attenuated Level 2 enclosure
  • Fuel System
    • Low fuel level alarm
    • Bunded fuel tank
    • Low fuel level shutdown
    • High fuel level alarm
  • Mounting Options
    • Battery removal
    • Electronic governor
    • Industrial silencer
    • External single point lift – enclosure
    • Silencer installation kit
  • Special Packing/inspectons For Shipment
    • PGS Test report @ 0.8 power factor
    • PGS Test report @ 1.0 power factor
  • General – Accessories / Miscellaneous
    • Packing case – canopied set