D300 GC (60 Hz) Generator Set

masthead-innerpage-bg

D300 GC (60 Hz) Generator Set

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Take Virtual Tour

Sorry, there aren’t current any videos for this product.

Sorry, there aren’t current any deals for this product.

https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-3ea27-3a140

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-da108-96542

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-92f47-79cda

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-30ae2-ee87d

  • User-friendly interface and navigation
  • Expansion modules and site-specific programming for specific customer requirements
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-0d295-12b36

  • Designed to operate in standard ambient temperatures up to104°F (40°C)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-71514-a5220

  • UL 2200 Listed
  • ULC Certification Available
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-0978e-242c4

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
https://s7d2.scene7.com/is/image/Caterpillar/CM20191227-90e57-21189

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Maximum Rating
300 ekW
Minimum Rating
300 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
Cat® C9 In-line 6, 4-cycle diesel
Bore
4.4in
Stroke
5.9in
Displacement
538in³
Compression Ratio
16.3:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
HEUI
Governor Type
Adem™A4
Length – Maximum
155.5in
Width – Minimum
56.3in
Width – Maximum
56.7in
Height – Minimum
67.2in
Height – Maximum
86.7in
Dry Weight – Genset (minimum)
5518.2lb
Dry Weight – Genset (maximum)
6929.1lb
  • Air Inlet System
    • Aftercooler core
    • Turbocharger
    • Air cleaner – Non canister, disposable
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Jacket water pump, gear driven, centrifugal
    • Thermostats and housing
    • Coolant drain valve
    • Radiator sight gauge
    • Blower fan and fan drive with guards
    • Radiator, package mounted
  • Exhaust System
    • Exhaust manifold – dry
  • Fuel System
    • Integral tank base, 24 hours, UL142
    • Fuel priming pump
    • Engine fuel transfer pump
    • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Generator Set
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • All protective devices and control functions simulated and checked
    • Factory tested to design specifications at full load conditions
  • Generators And Generator Attachments
    • IP23 Protection
    • 12 Leads
    • Insulation system, Class H
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • Voltage regulator (single phase sensing)
    • Easy access to AVR and terminals
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Shallow oil pan
    • Oil cooler
    • Fumes disposal to front of radiator
    • Oil drain with valve
    • Oil filler and dipstick
    • Oil filter, spin on
    • Lubricating oil, CK-4 (10W-30)
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Protection
    • Safety shutoff – High water temperature
    • Safety shutoff – Low oil pressure
    • Safety shutoff – Overspeed
  • Starting/charging System
    • 24-volt electric starting motor
    • 24V, 45 Amp Charging alternator
  • General
    • Lifting eyes
    • Vibration damper
    • Parts book
  • Air Inlet System
    • Air cleaner (Non canister disposable)
  • Bases, Mounting & Fuel Tanks
    • Integral tank base, 24 hours, UL142
    • Audio & visual fuel alarm (@90% fuel level)
    • Wide Base – Skid
    • Fuel tank pill pipe & lockable cap
  • Circuit Breaker
    • 400A LSI
    • 600A LSI
    • 1200A LSI
    • 800A LS/I
    • Auxiliary contacts
    • 600A LS/I
    • 1200A LS/I
    • 400A LS/I
    • 800A LSI
  • Control System
    • Audible alarm Gp
    • 16 -light NFPA 99/110 Annunciator
    • Twist release, Red button emergency stop
    • Ground fault relay
    • 100A Load center
    • Product link remote monitoring hardware
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • Volt free contacts
  • Enclosures
    • Sound attenuated Level 2 enclosure (White)
    • AC & DC Source lights
    • E-Stop
  • Exhaust System
    • 6″ Muffler – 25 dBA attenuation
    • Manifold and turbocharger guards
    • Flexible exhaust connection
  • Generator
    • Space heater
    • Permanent magnet excitation (PMG) generator
  • Starting System
    • Battery charger (UL Certified)
    • Jacket water heater
    • Standard battery set: 1000 CCA, 90 amp/hr.
  • General
    • CSA Certification
    • Extended Service Coverage
    • UL2200 Certification
    • Generator test report