  • Cat generator set packages have been fully prototype tested
  •     
  • Meets NFPA 110 loading requirements
  •     
  • Conform to ISO 8528-5 steady state and transient response requirements

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

        
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities

  • UL 2200 Listed
  • ULC Certification Available

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standby Rating
80 ekW
Frequency
60 Hz
Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified
Voltage
208 to 600 Volts
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
269in³
Compression Ratio
16.7:1
Aspiration
Turbocharged
Fuel System
Common Rail
Governor Type
Mechanical, ADEM™A4
Length – Maximum
82.6in
Width – Maximum
43.3in
Height – Maximum
52.9in
Dry Weight – Genset (maximum)
950lb
  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Cooling System
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Coolant drain line with valve
  • Control Panel
    • GCCP 1.2 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use – shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
  • Generator
    • Voltage regulator (single phase sensing)
    • Segregated low voltage (AC/DC) wiring panel
    • Tower panel, IP22, bottom cable entry
  • Governing System
    • Mechanical and electrical governing system – model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Includes lifting provision and drag points
    • Termination points for coolant and lube oil drain lines
    • Captive linear vibration isolators between base and engine-generator
  • Starting/charging System
    • Batteries
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Telematics
    • Cat® Product Link™ PL444 cellular
  • Alternator System
    • 3 Phase sensing
    • Anti-condensation heater
    • Permanent magnet excitation (PMG)
  • Circuit Breakers
    • Circuit breaker upgrades – 4 Pole circuit reaker to 250A, 400A and 630 A
  • Cooling System
    • Low coolant level shutdown
    • Coolant heater
    • Low coolant temperature alarm
  • Control Panel Options
    • Earth fault (2 wire only)
    • Panel mounted audible alarm
    • Battery charger
    • Control panel heater
    • Voltage adjust potentiometer
    • Emergency stop with key
  • Enclosures
    • Sound attenuated Level 2 enclosure
  • Fuel System
    • High fuel level alarm
    • Open set narrow tankbase
    • Low fuel level alarm
    • Low fuel level shutdown
    • Compact skidbase for open set
    • Skidbase for CALG enclosure sets
  • Global Certifications
    • Certification for CIS
  • Mounting Options
    • Industrial silencer
    • Electronic governor
    • External single point lift – enclosure
    • Silencer installation kit
  • General – Accessories / Miscellaneous
    • Stone guards/rad trans flange
    • Packing case – canopied set
    • Packing case – compact set

Take the virtual product tour