Power Grid Stabilization (PGS) Heavy Duty mobile module
Electric Power
Electric Power (355)
-
G70LG2 Gas Generator Set
-
G80LG6 Gas Generator Set
-
G45LG2 Gas Generator Set
-
G230LG6 Gas Generator Set
-
GEUG16-1 Gas Generator Set
-
G300LG6 Gas Generator Set
-
G200LG6 Gas Generator Set
-
G130LG4 Gas Generator Set
-
G25LTA2 Gas Generator Set
-
GES550-1
-
Emergency Transfer Load manager
-
Photovoltaic Module PVT
-
Cat® Microgrid Master Controller (MMC-M)
-
XG400
-
XQ2000
-
XQE20
-
XQE30
-
XQ800
-
XQ100
-
XG400 – Natural Gas
-
550kW
-
XQP275
-
XQ1475G
-
G20CM34
-
G3520E Gas Generator Set
-
Gas Generator G3516B
-
DG100-2 (3 Phase)
-
DG125-2 (3 Phase)
-
DG150-2 (3 Phase)
-
DG80-2 (Single Phase)
-
DG80-2 (3 Phase)
-
DG100-2S (Single Phase)
-
DG50-2 (Single Phase)
-
DG50-2 (3 Phase)
-
DG60-2 (Single Phase)
-
DG60-2 (3 Phase)
-
DG275-2 (Single-phase)
-
DG350-2 (Single-phase)
-
DG400-2 (Single-phase)
-
DG230-2 (Single phase)
-
DG250-2 (Single-phase)
-
CG132-12 Gas Generator Set
-
G3508A
-
Gas Generator CG132
-
CM43C (Inline)
-
CM46DF (V-Type)
-
CM32C (Inline) Generator Set
-
CM32C (V-Type) Generator Set
-
CM32E
-
C27 Tier 4 Interim
-
CM25E Generator Set
-
DE800 GC
-
C15 Tier 4 Interim
-
3516E High Voltage Generator Set
-
C32 Generator Set with Upgradeable Packaging
-
3516B (50 Hz) with Upgradeable Package
-
GEP100-1
-
GEP125-1
-
GEP169-1
-
GEP218-3
-
MX150 Microprocessor Controller
-
MX250 Microprocessor Controller
-
MX350 Controller
-
CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch
-
CTS Series Automatic Transfer Switch
-
CTX Series Automatic Transfer Switch
-
CTSM and CTGM Series Manual Transfer Switches
-
ATC-800 CONTROLLER
-
CTE Series Automatic Transfer Switch
-
ATC-300+ CONTROLLER
-
CTG Series Automatic Transfer Switch
-
ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
-
ATC Power Breaker & Case Switch Automatic Transfer Switch
-
ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch
-
ATC Service Entrance Rated MCCB & Power Breaker Based ATS
-
ATC Contactor-Based Automatic Transfer Switch
-
Cat Switchgear
-
ATC Contactor Based Bypass Isolation Automatic Transfer Switch
-
Cat EGP Switchgear
-
Cat XLM Switchgear
-
EMCP 4.4 Master Control Panel
-
Cat Customizable Switchgear and Controls
-
Engine Paralleling and Integration Control (EPIC)
-
XES60 (50 Hz)
-
XES60 (60 Hz)
-
XES120 (50 Hz)
-
XES120 (60 Hz)
-
Photovoltaic Module PVC
-
Photovoltaic Module PVC
-
Photovoltaic Module PVC
-
Photovoltaic Module PVC
-
Power Grid Stabilization (PGS) module
-
Energy Capacity Expansion (ECE) module
-
Power Grid Stabilization (PGS) Heavy Duty mobile module
-
Energy Time Shift (ETS) Module
-
Cat® Microgrid Master Controller-Small (MMC-S)
-
Cat® BDP1000 Bi-Directional Power Inverter
-
Cat® Microgrid Master Controller-M (MMC-M)
-
Temporary Connection Boxes
-
XGC1900
-
XQ2280 Tier 4 Final
-
XGC1900
-
XQC1600
-
XQ1140 T4 Final – Diesel
-
XQP1100 Rental Generator Set
-
XQC1200
-
XQP500
-
XQ425
-
XQ570 Tier 4 Final – 455 ekW (568 kVA)
-
XQP550 EU Stage V
-
XQP300
-
XQ230 Rental Power
-
XQP310 EU Stage V
-
XQ330 Tier 4 Final (264 ekW, 330 kVA)
-
XQ125 Rental Power
-
XQP150
-
XQP200 EU Stage V
-
XQP115 EU Stage V
-
XQP100
-
XQP60
-
XQ60
-
XQ35
-
XQP30 – Diesel
-
CG260-16 Gas Generator Set
-
CG260-16 Gas Generator Set
-
XQP20 EU Stage V
-
CG170-20 Gas Generator Set
-
CG260 Gas Generator Set
-
CG170-20B Gas Generator Set
-
CG170 Gas Generator Set
-
CG170 Gas Generator Set
-
CG170B-12 Gas Generator Set
-
CG170B-16 Gas Generator Set
-
Gas Generator CG132B-16
-
Gas Generator CG132B-16
-
CG170-12 KGas Generator Set
-
CG170-12 Gas Generator Set
-
G3520H Gas Generator
-
CG132B-8 Gas Generator Set
-
CG132B-12 Gas Generator Set
-
Cat G3520H Combined Heat and Power (CHP) Solution
-
G3520C Gas Generator
-
G3520 2000kW Gas Generator Set
-
G3520 2500kW Gas Generator Set
-
Cat G3516H Combined Heat and Power (CHP) Solution
-
Gas Generator G3516A
-
G3516C Gas Generator Set
-
Gas Generator G3516H
-
G3516 1500kW Gas Generator Set
-
G3512E Gas Generator Set
-
Gas Generator G3512H
-
Cat G3512H Combined Heat and Power (CHP) Solution
-
G3412 Gas Generator Set
-
G3512 750kW Gas Generator Set
-
G3512 1000kW Gas Generator Set
-
G3412 Gas Generator Set
-
DG450-2 (Single-phase)
-
G3406 Gas Generator Set
-
DG500 (60 Hz)
-
DG450 (3-Phase)
-
DG350-2 (Single-phase)
-
DG400-2 (Three phase)
-
DG350 (3-Phase)
-
DG400 (3-Phase)
-
DG230-2 (3 phase)
-
DG250-2 (3 phase)
-
DG275-2 (3 phase)
-
DG300-2 (3 phase)
-
DG175-2 (3 phase)
-
DG200-2 (3 phase)
-
DG200-2S (Single-phase)
-
DG175-2 (Single-phase)
-
DG100 (60 Hz)
-
DG125 (Single-phase and 3 phase) (60 Hz)
-
DG150 (3 phase) (60 Hz)
-
3616 Generator Set (Medium Speed)
-
C280-12 Generator Set (Medium Speed)
-
3616 Generator Set (Medium Speed)
-
C280-16 Generator Set (Medium Speed)
-
3608 Generator Set (Medium Speed)
-
3612 Generator Set (Medium Speed)
-
C280-8 Generator Set (Medium Speed)
-
3612 Generator Set (Medium Speed)
-
3606 Generator Set (Medium Speed)
-
3606 Generator Set (Medium Speed)
-
C280-6 Generator Set (Medium Speed)
-
3608 Generator Set (Medium Speed)
-
C175-16 Tier 4 Final
-
C175-20
-
C175-16 Generator Set
-
C175-20
-
3516E Low Voltage Generator Set
-
3516E Generator Set
-
C175-16 Generator Set
-
3516E Low Voltage Generator Set
-
3516C Tier 4 Final
-
3516E Low Voltage Generator Set
-
3516E Generator Set
-
3516C Generator Set
-
3516C (50 Hz) with Upgradeable Package
-
3516C Generator Set
-
3516C Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516B (60 Hz) with Upgradeable Package
-
3516B (50 Hz) Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516 Diesel Generator Set
-
3516B Generator Set
-
3516 Diesel Generator Set
-
3516B (50 Hz) India Market Only
-
3516 Diesel Generator Set
-
3512C Generator Set
-
3516 Diesel Generator Set
-
3512B Diesel Generator Set
-
3512C Generator Set
-
3512B Diesel Generator Set
-
3512B Diesel Generator Set
-
3512 Generator Set
-
3512 with Upgradeable Package
-
3512B (50 Hz) India Market Only
-
3512B (50 Hz) Generator Set
-
C32 (60 Hz)
-
3512 Generator Set
-
3512 Generator Set
-
D1250 GC
-
DE1250 GC (50 Hz)
-
DE1250S GC
-
DE1400 GC
-
DE1500 GC
-
D1000 GC
-
DE1100 GC
-
C32 Generator Set
-
C27 Generator Set
-
C32 (50 Hz) India Market Only
-
DE1000S GC
-
DE800S GC
-
3412C Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
3412C Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
D600 GC (60 Hz) Generator Set
-
DE715 GC Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
DE600S GC Generator Set
-
C18 Generator Set
-
D550 GC (60 Hz) Generator Set
-
C18 (50 Hz) India Market Only
-
C15 Generator Set
-
DE550S GC (60 Hz) Generator Set
-
DE660 GC (50 Hz) Generator Set
-
C15 Generator Set
-
D500 GC (60 Hz) Generator Set
-
DE605 GC (50 Hz) Generator Set
-
DE500S GC (60 Hz) Generator Set
-
D450 GC (60 Hz) Generator Set
-
C15 Generator Set
-
C15 (50 Hz) China Non Road
-
DE450S GC (60 Hz) Generator Set
-
C13 Generator Set
-
C13 Generator Set
-
C15 (50 Hz) India Market Only
-
DE550 GC (50 Hz) Generator Set
-
D400 GC (60 Hz) Generator Set
-
DE450 GC (50 Hz) Generator Set
-
C13 (50 Hz) China Non Road
-
DE500 GC (50 Hz) Generator Set
-
D350 GC (60 Hz) Generator Set
-
DE400 GC Generator Set
-
C13 (50 Hz) India Market Only
-
C13 Generator Set
-
C9 Generator Set
-
C9 Generator Set
-
DE400S GC Generator Set
-
D300 GC (60 Hz) Generator Set
-
D250 GC (60 Hz) Generator Set
-
DE350S GC Generator Set
-
C9 Generator Set
-
C7.1 Generator Set
-
C7.1 ACERT
-
D200 GC Generator Set
-
DE220 GC (50 Hz) Generator Set
-
C7.1 ACERT
-
D175 GC Generator Set
-
DE200 GC Generator Set (60 Hz)
-
DE165 GC Generator Set (60 Hz)
-
DE218AE0 (60 Hz) Generator Set
-
D150 GC Generator Set
-
DE169AE0 (60 Hz) Generator Set
-
DE218AE0 (50 Hz) Generator Set
-
DE200 GC Generator Set (50 Hz)
-
D125 GC Generator Set
-
DE169AE0 (50 Hz) Generator Set
-
DE165 GC Generator Set (50 Hz)
-
DE150 GC Generator Set (60 Hz)
-
C4.4 Generator Set
-
C4.4 Generator Set
-
DE150 GC Generator Set (50 Hz)
-
C4.4 Generator Set
-
D100 GC Generator Set
-
DE110 GC Generator Set (60 Hz)
-
DE125AE0 (60 Hz) Generator Set
-
DE100AE0 (60 Hz) Generator Set
-
DE88 GC Generator Set (60 Hz)
-
DE110 GC Generator Set (50 Hz)
-
DE125AE0 (50 Hz) Generator Set
-
D80 GC Generator Set
-
DE88 GC Generator Set (50 Hz)
-
DE100AE0 (50 Hz) Generator Set
-
C3.3 Generator Set
-
C4.4 Generator Set
-
D60 GC Generator Set
-
DE65 GC Generator Set (60 Hz)
-
DE75AE0 (50 Hz) Generator Set
-
DE65 GC Generator Set (50 Hz)
-
C3.3 Generator Set
-
DE75AE0 (60 Hz) Generator Set
-
D50 GC Generator Set
-
DE50 GC Generator Set (60 Hz)
-
DE56AE0 (60 Hz) Generator Set
-
DE55 GC Generator Set (60 Hz)
-
D40 GC Generator Set
-
DE56AE0 (50 Hz) Generator Set
-
DE50 GC Generator Set (50 Hz)
-
DE55 GC Generator Set (50 Hz)
-
DE33 GC Generator Set (50 Hz)
-
DE33 GC Generator Set (60 Hz)
-
C2.2 | D25 Generator Set
-
C2.2 | D30 Generator Set
-
C1.5 Generator Set
-
C2.2 Generator Set
-
C2.2 Generator Set
-
C2.2 | D20 Generator Set
-
C1.1 Generator Set
-
C1.1 Generator Set
-
C1.5 Generator Set
-
XQ 500
-
XQ 800
-
XQ 200
-
XQ1500
-
XQ1000
-
XQ400
-
XQ350
-
XQ300
-
XQ230
-
APS150
-
XQ100
-
XQ30
-
XQ2000
Overview
The Cat® Power Grid Stabilization Heavy Duty (PGS HD) mobile module is a scalable, rapidly deployable energy storage system. The PGS HD integrates with solar or other renewable sources to provide short duration power when the renewable source is not available. The PGS HD also provides reserve power to optimize generator set operation. The system may provide temporary backup power to facilities in the event of a power outage.
- Reliable, Scalable and Mobile
- Renewable Integration
- Transient Assist
- Grid Stabilization
- High Performance Inverter
- Applicable Standards and Certifications
Reliable, Scalable and Mobile
Factory prepackaged and tested
- Pre-engineered mobile containeron trailer with batteries, inverter, isolation transformer and other equipment installed.
- Multiple energy storage systems may be paralleled up to 100+MW
Renewable Integration
- Designed to work with an array of renewable systems, including solar and wind
- Seamless integration with Cat Microgrid Master Controller (MMC) allows for maximum renewable penetration and full asset control
Transient Assist
When used with a generator set, the Cat PGS module will provide reserve power capacity to:
- Decrease the transient voltage and frequency dips resulting from the application of large loads.
- Enables highly-efficient lean-burn gas gensets to operate in island mode.
Grid Stabilization
- Protects against many typical power problems, including power failure, voltage sags/surges, and under/over frequency conditions.
High Performance Inverter
- Built-in controls for the charging and discharging of the energy storage equipment.
- Static VAR compensator.
- Four-quadrant output power factor control.
- Aautomatic anti-islanding to meet UL 1741 and synchronization back to grid.
Applicable Standards and Certifications
UL Listed to the following standards (certification and mark pending):
- UL 9540
- UL 1741 SB
- CSA C22.2 No. 107.1/16
- cULus mark
- CE Declaration of conformity
- IEC60204-1
Reliable, Scalable and Mobile
Factory prepackaged and tested
- Pre-engineered mobile containeron trailer with batteries, inverter, isolation transformer and other equipment installed.
- Multiple energy storage systems may be paralleled up to 100+MW
Renewable Integration
- Designed to work with an array of renewable systems, including solar and wind
- Seamless integration with Cat Microgrid Master Controller (MMC) allows for maximum renewable penetration and full asset control
Transient Assist
When used with a generator set, the Cat PGS module will provide reserve power capacity to:
- Decrease the transient voltage and frequency dips resulting from the application of large loads.
- Enables highly-efficient lean-burn gas gensets to operate in island mode.
Grid Stabilization
- Protects against many typical power problems, including power failure, voltage sags/surges, and under/over frequency conditions.
High Performance Inverter
- Built-in controls for the charging and discharging of the energy storage equipment.
- Static VAR compensator.
- Four-quadrant output power factor control.
- Aautomatic anti-islanding to meet UL 1741 and synchronization back to grid.
Applicable Standards and Certifications
UL Listed to the following standards (certification and mark pending):
- UL 9540
- UL 1741 SB
- CSA C22.2 No. 107.1/16
- cULus mark
- CE Declaration of conformity
- IEC60204-1
Technical Summary
- Application
- Transient Assist
- Module Type
- Heavy Duty mobile Grid Stabilization
- Rated Power
- 840-1260 kW
- Nameplate Power
- 1000 kW
- Nameplate Energy Capacity
- 672 kWh
Standard/Optional Features
Standard Equipment:
-
- Power Grid Stabilization
-
- Cat BDP bi-directional power inverter
- Energy storage batteries
- Color HMI touchscreen
- Remote communications via Modbus TCP
- HVAC system to maintain interior temperature
- Liquid / Air cooling
- Isolation Transformer
- Convenience receptacles
- Fire suppression system
- Transport trailer