XQ500
Electric Power
Electric Power (215)
-
UPS Generator Set Start Module
-
G80LG6 Gas Generator Set
-
G60LG2 Gas Generator Set
-
G70LG2 Gas Generator Set
-
G45LG2 Gas Generator Set
-
G50LG2 Gas Generator Set
-
G300LG6 Gas Generator Set
-
G35LG2 Gas Generator Set
-
G40LG2 Gas Generator Set
-
GEUG16-1 Gas Generator Set
-
G275LG6 Gas Generator Set
-
G200LG6 Gas Generator Set
-
G230LG6 Gas Generator Set
-
G175LG6 Gas Generator Set
-
G130LG4 Gas Generator Set
-
G150LG6 Gas Generator Set
-
G25LTA2 Gas Generator Set
-
G100LG4 Gas Generator Set
-
GES450-5
-
GES550-1
-
ATC-100 CONTROLLER
-
Engine Generator Integrated Switchgear
-
Photovoltaic Module PVT
-
Photovoltaic (PV) Module PVT115
-
XQ230
-
General Service ESS 48V DC
-
XG400
-
XQ2000
-
XQE20
-
XQE30
-
XQE60
-
XQ2000
-
XQ800
-
XQ500
-
XQ300
-
XQ200
-
XQ100
-
20-2000 kVA
-
300kW
-
550kW
-
400kW
-
DG450-2 (Single-phase)
-
DG350-2 (Single-phase)
-
DG400-2 (Single-phase)
-
DG230-2 (Single phase)
-
DG250-2 (Single-phase)
-
DG275-2 (Single-phase)
-
G3306 Gas Generator Set
-
CG132-8 Gas Generator Set
-
CG260-16 Gas Generator Set
-
CG132-12 Gas Generator Set
-
CG260 Gas Generator Set
-
G3512A Generator Set
-
Gas Generator CG132
-
G3508A
-
DG300-2 (Single-phase)
-
C15 Tier 4 Interim
-
C27 Tier 4 Interim
-
C6.6 Generator Set
-
D550 GC (60 Hz) Generator Set
-
3512B-HD (CTL) Generator Set
-
3516E High Voltage Generator Set
-
3516C Generator Set
-
3512B Diesel Generator Set
-
C13 Generator Set
-
C32 Generator Set with Upgradeable Packaging
-
C32 Generator Set with Upgradeable Packaging
-
3516B (50 Hz) with Upgradeable Package
-
GEP169-1
-
GEP218-3
-
GEP100-1
-
GEP125-1
-
MX250 Microprocessor Controller
-
MX350 Controller
-
CTX Series Automatic Transfer Switch
-
MX150 Microprocessor Controller
-
CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch
-
CTS Series Automatic Transfer Switch
-
CTSM and CTGM Series Manual Transfer Switches
-
CTE Series Automatic Transfer Switch
-
CTG Series Automatic Transfer Switch
-
ATC-300+ CONTROLLER
-
ATC-800 CONTROLLER
-
ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch
-
ATC Service Entrance Rated MCCB & Power Breaker Based ATS
-
ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
-
ATC Power Breaker & Case Switch Automatic Transfer Switch
-
ATC Contactor Based Bypass Isolation Automatic Transfer Switch
-
ATC Contactor-Based Automatic Transfer Switch
-
Cat Switchgear
-
Cat XLM Switchgear
-
Cat Customizable Switchgear and Controls
-
Cat EGP Switchgear
-
EMCP 4.4 Master Control Panel
-
Emergency Transfer Load manager
-
Engine Paralleling and Integration Control (EPIC)
-
Photovoltaic Module PVC
-
Photovoltaic Module PVC
-
Photovoltaic Module PVC
-
CAT® BDP 250 ENERGY STORAGE INVERTER
-
Temporary Connection Boxes
-
XGC1900
-
XQ1475G
-
XQC1600
-
XQC1200
-
XQP1100 Rental Generator Set
-
XQP500
-
XQ570
-
XQ425
-
XQP275
-
XQP300
-
XQP150
-
XQ230 Rental Power
-
XQ125 Rental Power
-
XG135 – Natural Gas
-
XQP60
-
XQP100
-
XQ35
-
XQ60
-
CG170-20 Gas Generator Set
-
CG170-12 Gas Generator Set
-
CG170 Gas Generator Set
-
G3520H Gas Generator
-
G3520C Gas Generator
-
G3520E Gas Generator Set
-
G3516C Gas Generator Set
-
Gas Generator G3516H
-
Gas Generator G3516A
-
Gas Generator G3516B
-
G3512E Gas Generator Set
-
Gas Generator G3512H
-
G3412 Gas Generator Set
-
G3512 750kW Gas Generator Set
-
G3512 1000kW Gas Generator Set
-
G3406 Gas Generator Set
-
DG400-2 (Three phase)
-
DG450-2 (Single-phase)
-
DG300-2 (3 phase)
-
DG350-2 (Single-phase)
-
DG250-2 (3 phase)
-
DG275-2 (3 phase)
-
DG200-2 (3 phase)
-
DG230-2 (3 phase)
-
DG175-2 (Single-phase)
-
DG175-2 (3 phase)
-
DG200-2S (Single-phase)
-
DG125-2 (3 Phase)
-
DG150-2 (3 Phase)
-
DG100-2S (Single Phase)
-
DG100-2 (3 Phase)
-
DG80-2 (Single Phase)
-
DG80-2 (3 Phase)
-
DG60-2 (Single Phase)
-
DG60-2 (3 Phase)
-
DG50-2 (Single Phase)
-
DG50-2 (3 Phase)
-
3616 Generator Set (Medium Speed)
-
CM20C Generator Set
-
3608 Generator Set (Medium Speed)
-
3612 Generator Set (Medium Speed)
-
3606 Generator Set (Medium Speed)
-
C175-20
-
C175-16 Tier 4 Final
-
C175-16 Generator Set
-
3516E Low Voltage Generator Set
-
3516C Generator Set
-
3516C Tier 4 Final
-
3516B Generator Set
-
3516B Generator Set
-
3516B (50 Hz) Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516 Diesel Generator Set
-
3516 Diesel Generator Set
-
3516 Diesel Generator Set
-
3512C Generator Set
-
3512B Diesel Generator Set
-
3512C Generator Set
-
3512 Generator Set
-
C32 (60 Hz)
-
3412C Generator Set
-
C27 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C15 Generator Set
-
C15 Generator Set
-
C13 Generator Set
-
C13 Generator Set
-
C9 Generator Set
-
C9 Generator Set
-
C7.1 Generator Set
-
C7.1 ACERT
-
C4.4 Generator Set
-
C4.4 Generator Set
-
C7.1 ACERT
-
C4.4 Generator Set
-
C3.3 Generator Set
-
C4.4 Generator Set
-
C1.1 Generator Set
-
C1.5 Generator Set
-
XQ 500
-
XQ 800
-
XQ 200
-
XQ1500
-
XQ1000
-
XQ400
-
XQ350
-
XQ300
-
XQ230
-
APS150
-
XQ100
-
XQ30
-
XQ2000
Overview
Generator
- Rating
- 500 ekW (625 kVA) Standby
Dimensions
- Width
- 96.0in
- Height
- 150.0in
- Length
- 240.0in
- Weight
- 35045.0lb
- Width
- 96in
- Height
- 150in
- Length
- 240in
- Weight
- 35045lb
Generator Set
- Prime Rating
- 455 ekW (568 kVA)
- Voltage
- 208 - 480 V
- Frequency
- 60 Hz
- Rating
- 500 ekW (625 kVA) Standby
Engine
- Engine
- C15 TIer 4 Interim
- Fuel
- Diesel
Standard/Optional Features
Standard Equipment:
-
- C15 Tier 4 Interim Ataac Diesel Engine
-
- Utilizes ACERT Technology
- Reliable, rugged, durable design
- Four-stroke-cycle diesel engine combines durability with minimum weight while providing dependability and economy
- Electronic Engine Control
-
- Cat Generator
-
- Designed to match performance and output characteristics of diesel engines
- Single point access to accessory connections
- UL 1446 Recognized Class H insulation
-
- Sound Attenuated Enclosure
-
- 20' ISO high cube container
- Spill containment 110% of all engine fluids
- External drain access to standard fluids
- Meets 72 dB(A) at 7 meters or below per SAE J1074 measurement procedure at 110% prime load
-
- Reduced Environmental Impact
-
- Sound attenuated for low noise operation
- OSHA Compliant safe design
- 110% spill containment for cooland and oil
- UL142 certified dual wall fuel tank
-
- Cat Digital Voltage Regulator (cdvr)
-
- Three-phase sensing
- Adjustable volts-per-hertz regulation
- Provides precise control, excellent block loading, and constant voltage in the normal operating range
-
- Cat Emcp 4.4 Control Panel
-
- Simple user friendly interface and navigation
- Integrated, automatic genset paralleling, facilitates multi-unit systems meeting a wide range of customer applications
- Integrated control system and communication gateway