Photovoltaic Module PVC
Electric Power
Electric Power (218)
-
UPS Generator Set Start Module
-
G80LG6 Gas Generator Set
-
G60LG2 Gas Generator Set
-
G70LG2 Gas Generator Set
-
G45LG2 Gas Generator Set
-
G50LG2 Gas Generator Set
-
G300LG6 Gas Generator Set
-
G35LG2 Gas Generator Set
-
G40LG2 Gas Generator Set
-
GEUG16-1 Gas Generator Set
-
G275LG6 Gas Generator Set
-
G200LG6 Gas Generator Set
-
G230LG6 Gas Generator Set
-
G175LG6 Gas Generator Set
-
G150LG6 Gas Generator Set
-
G130LG4 Gas Generator Set
-
G100LG4 Gas Generator Set
-
G25LTA2 Gas Generator Set
-
GES550-1
-
ATC-100 CONTROLLER
-
GES450-5
-
Engine Generator Integrated Switchgear
-
Photovoltaic Module PVT
-
Heavy Duty ESS 48V DC
-
Photovoltaic (PV) Module PVT115
-
General Service ESS 48V DC
-
XQ230
-
XG400
-
XQ2000
-
XQE30
-
XQE60
-
XQ2000
-
XQE20
-
XQ500
-
XQ800
-
XQ200
-
XQ100
-
XQ300
-
20-2000 kVA
-
300kW
-
550kW
-
400kW
-
DG450-2 (Single-phase)
-
DG275-2 (Single-phase)
-
DG350-2 (Single-phase)
-
DG400-2 (Single-phase)
-
DG230-2 (Single phase)
-
DG250-2 (Single-phase)
-
G3306 Gas Generator Set
-
CG132-8 Gas Generator Set
-
CG260-16 Gas Generator Set
-
CG132-12 Gas Generator Set
-
CG260 Gas Generator Set
-
Gas Generator G3516E
-
Gas Generator CG132
-
G3508A
-
G3512A Generator Set
-
DG300-2 (Single-phase)
-
C27 Tier 4 Interim
-
C6.6 Generator Set
-
C15 Tier 4 Interim
-
D550 GC (60 Hz) Generator Set
-
3512B-HD (CTL) Generator Set
-
3516E High Voltage Generator Set
-
3516C Generator Set
-
3512B Diesel Generator Set
-
C32 (60 Hz) with Upgradeable Packaging
-
C13 Generator Set
-
C32 Generator Set with Upgradeable Packaging
-
C32 Generator Set with Upgradeable Packaging
-
3516B (50 Hz) with Upgradeable Package
-
GEP218-3
-
GEP100-1
-
GEP125-1
-
GEP169-1
-
MX250 Microprocessor Controller
-
MX350 Controller
-
CTX Series Automatic Transfer Switch
-
MX150 Microprocessor Controller
-
CTS Series Automatic Transfer Switch
-
CTSM and CTGM Series Manual Transfer Switches
-
CTE Series Automatic Transfer Switch
-
CTG Series Automatic Transfer Switch
-
CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch
-
ATC-300+ CONTROLLER
-
ATC-800 CONTROLLER
-
ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch
-
ATC Service Entrance Rated MCCB & Power Breaker Based ATS
-
ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
-
ATC Power Breaker & Case Switch Automatic Transfer Switch
-
ATC Contactor Based Bypass Isolation Automatic Transfer Switch
-
ATC Contactor-Based Automatic Transfer Switch
-
Cat Customizable Switchgear and Controls
-
Cat Switchgear
-
Cat EGP Switchgear
-
Cat XLM Switchgear
-
EMCP 4.4 Master Control Panel
-
Emergency Transfer Load manager
-
Engine Paralleling and Integration Control (EPIC)
-
Photovoltaic Module PVC
-
Photovoltaic Module PVC
-
Photovoltaic Module PVC
-
CAT® BDP 250 ENERGY STORAGE INVERTER
-
Temporary Connection Boxes
-
XGC1900
-
XQC1200
-
XQC1600
-
XQP1100 Rental Generator Set
-
XQ1475G
-
XQP500
-
XQ570
-
XQ425
-
XQP275
-
XQP300
-
XQP150
-
XQ230 Rental Power
-
XQ125 Rental Power
-
XG135 – Natural Gas
-
XQP60
-
XQP100
-
XQ35
-
XQ60
-
CG170-20 Gas Generator Set
-
CG170-12 Gas Generator Set
-
CG170 Gas Generator Set
-
G3520H Gas Generator
-
G3520E Gas Generator Set
-
Gas Generator G3516H
-
G3520C Gas Generator
-
Gas Generator G3516B
-
G3516C Gas Generator Set
-
Gas Generator G3516A
-
Gas Generator G3512H
-
G3512E Gas Generator Set
-
G3512 1000kW Gas Generator Set
-
G3412 Gas Generator Set
-
G3512 750kW Gas Generator Set
-
G3406 Gas Generator Set
-
DG350-2 (Single-phase)
-
DG400-2 (Three phase)
-
DG450-2 (Single-phase)
-
DG275-2 (3 phase)
-
DG300-2 (3 phase)
-
DG230-2 (3 phase)
-
DG250-2 (3 phase)
-
DG200-2 (3 phase)
-
DG200-2S (Single-phase)
-
DG175-2 (Single-phase)
-
DG175-2 (3 phase)
-
DG150-2 (3 Phase)
-
DG100-2 (3 Phase)
-
DG125-2 (3 Phase)
-
DG80-2 (3 Phase)
-
DG100-2S (Single Phase)
-
DG60-2 (3 Phase)
-
DG80-2 (Single Phase)
-
DG50-2 (3 Phase)
-
DG60-2 (Single Phase)
-
DG50-2 (Single Phase)
-
CM20C Generator Set
-
3608 Generator Set (Medium Speed)
-
3612 Generator Set (Medium Speed)
-
3616 Generator Set (Medium Speed)
-
3606 Generator Set (Medium Speed)
-
C175-16 Tier 4 Final
-
C175-20
-
3516E Low Voltage Generator Set
-
C175-16 Generator Set
-
3516C Tier 4 Final
-
3516C Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516B (50 Hz) Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516 Diesel Generator Set
-
3516 Diesel Generator Set
-
3516 Diesel Generator Set
-
3512C Generator Set
-
3512B Diesel Generator Set
-
3512C Generator Set
-
3512 Generator Set
-
C32 (60 Hz)
-
3412C Generator Set
-
C27 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C15 Generator Set
-
C15 Generator Set
-
C13 Generator Set
-
C13 Generator Set
-
C9 Generator Set
-
C9 Generator Set
-
C7.1 Generator Set
-
C7.1 ACERT
-
C4.4 Generator Set
-
C7.1 ACERT
-
C4.4 Generator Set
-
C4.4 Generator Set
-
C3.3 Generator Set
-
C4.4 Generator Set
-
C1.1 Generator Set
-
C1.5 Generator Set
-
XQ 500
-
XQ 800
-
XQ 200
-
XQ1500
-
XQ1000
-
XQ400
-
XQ350
-
XQ300
-
XQ230
-
APS150
-
XQ100
-
XQ30
-
XQ2000
Overview
The mono crystalline halfcut PERC (passivated emitter rear cell) photovoltaic modules provide excellent performance with low temperature coefficient. The modules provide high efficiency and power per module, maximizing energy capture.
- Higher Efficiency
- Increase Energy Production
- More durable / Reliable
- 25 year power output warranty
- Tests and Certificates
Higher Efficiency
Higher Efficiency
- The panel design provides excellent performance under low temperature or low light environment.
Increase Energy Production
Increase Energy Production
- Reduced resistive losses and an optimized electrical design result in higher energy yield.
More durable / Reliable
More durable / Reliable
- Durability tested for mechanical load; Dynamic + Thermal Cycle + Humidity Freeze
- Harsh evironments; salt mist, amonia, dust and sand.
25 year power output warranty
Warranty
- Standard 25 year warranty on manufacturer defects and a 25 year power output warranty
Tests and Certificates
Tests and Certificates
- IEC 61215, IEC 61730 Class C according to UL790
- UL 1730 Type 1 fire rating
- IEC 61701 (maximum severity) Salt Spray Test
- IEC62716 Ammonia Test
- IEC 60068, Dust and Sand test
- Listings: TUV SUD, CSA, CE
- ISO 9001:2008: ISO Quality Management System
- ISO 14001:2004: ISO Environment Management System
Higher Efficiency
Higher Efficiency
- The panel design provides excellent performance under low temperature or low light environment.
Increase Energy Production
Increase Energy Production
- Reduced resistive losses and an optimized electrical design result in higher energy yield.
More durable / Reliable
More durable / Reliable
- Durability tested for mechanical load; Dynamic + Thermal Cycle + Humidity Freeze
- Harsh evironments; salt mist, amonia, dust and sand.
25 year power output warranty
Warranty
- Standard 25 year warranty on manufacturer defects and a 25 year power output warranty
Tests and Certificates
Tests and Certificates
- IEC 61215, IEC 61730 Class C according to UL790
- UL 1730 Type 1 fire rating
- IEC 61701 (maximum severity) Salt Spray Test
- IEC62716 Ammonia Test
- IEC 60068, Dust and Sand test
- Listings: TUV SUD, CSA, CE
- ISO 9001:2008: ISO Quality Management System
- ISO 14001:2004: ISO Environment Management System
- TS62941: Guideline for module design qualification and type approval
- OHSAS 18001: 2007 Occupational Health and Safety
Technical Summary
- Nominal Power
- 365W to 440W per panel
- Application
- Compatible with 1000V and 1500V plant architectures
- Module Type
- Mono crystalline halfcut PERC
Standard/Optional Features
Standard Equipment:
-
- Power Assurance Program For Linear Power Output.
-
- Produces more than 97.5% power in the first year and after 25 years 85.5%.
-
- Durability Test Cycle (accelerated Tests)
-
- 2000 hrs damp heat testing is twice the standard testing hrs. required
- 600 thermal cycling testing is three times the standard cycles required.
- 192 hrs of PID (potential-induced degradation) at 85°C/85RH) is twice the standard testing hrs. required.
- Mechanical Load testing for Dynamic + Thermal Cycle + Humidity Freeze result in much less cell breakage and power loss than static testing alone.
- 60-100 kWh/m2 LID (light-induced- degradation) validates early hour performance.
- LeTID (light and elevated temperature degradation) is a proprietary validation for long term PERC performance.
- Validated for use in harsh environment by IEC testing for salt mist, amonia, dust and sand.