C9 Genset  Marine Generator Sets

C9 Generator Set Package

Overview

The Caterpillar C9 generator set joins our existing range of clean, quiet, compact, and smooth-running generator sets. This range of small gen sets provides customers with a more comprehensive power offering, enabling them to enjoy the benefit of dealing with one supplier for both propulsion and auxiliary power.

500 hour oil & filter change interval
Smokeless engine operation meets 2004 EPA Tier II emission regulations
Leak free engine operation
J1939 data link for communication with ship monitoring, and control systems
Compact design
Caterpillar standard warranty
Parts and service support from worldwide dealer organization
One source of supply for propulsion and gen set engines
Optional duplex fuel and oil filter systems
Complete electronic control of fuel injection and engine timing
500 hour oil & filter change interval
Smokeless engine operation meets 2004 EPA Tier II emission regulations
Leak free engine operation
J1939 data link for communication with ship monitoring, and control systems
Compact design
Caterpillar standard warranty
Parts and service support from worldwide dealer organization
One source of supply for propulsion and gen set engines
Optional duplex fuel and oil filter systems
Complete electronic control of fuel injection and engine timing

Generator Set Specifications

Minimum Rating
142R ekW (178 kVA)
Maximum Rating
250 ekW (313 kVA)
Frequency
50 hz or 60hz
Speed
1500 rpm (50hz) or 1800 rpm (60 hz)
Minimum Rating
142R ekW (178 kVA)
Maximum Rating
250 ekW (313 kVA)
Frequency
50 hz or 60hz
Speed
1500 rpm (50hz) or 1800 rpm (60 hz)
Emissions/Fuel Strategy
IMO/EPA Tier 2 Compliant

Generator Set Configurations

Emissions/Fuel Strategy
IMO/EPA Tier 2 Compliant

Engine Specifications

Engine Model
C9, In-line 6, 4-Stroke-Cycle Diesel
Aspiration
Turbocharged-Aftercooled
Bore
4.41in
Stroke
5.87in
Displacement
538.0in3
Governor Type
Electronic
Fuel System
HEUI™
Aspiration
Turbocharged-Aftercooled
Bore
4.41in
Stroke
5.87in
Displacement
538in
Governor Type
Electronic
Engine Model
C9, In-line 6, 4-Stroke-Cycle Diesel

Generator Set Dimensions

Width
39.2in
Height
46.0in
Weight
1753 kg (3865 lb) - 1903 kg (4195 lb)
Length
2106-2216 mm (82.9-87.2 in)
Width
39.2in
Height
46in
Weight
1753 kg (3865 lb) - 1903 kg (4195 lb)

Generator Specifications

Excitation
AREP
Pitch
2/3
Number of Leads
12 lead, reconnectable
Insulation
Class H
IP Rating
IP23 Water protection
Overspeed Capability
Overspeed shutoff - electronic
Voltage Regulator
Solid state voltage regulator with integral voltage adjustment
Voltage Regulation
±0.5%

Standard/Optional Features

Standard Equipment:

  • Air Inlet System
    • Aftercooler (heat exchanger and keel cooled engines only)
    • Turbocharger
  • Control Panels
    • Electronic governor
    • Hydraulic Electronic Unit Injection (HEUI) fuel system
    • Electronic Control Module (ECM)
    • Electronic diagnostics and fault logging
    • Engine mounted 40-pin dedicated customer connector
    • SAE J1939 data link
  • Cooling System
    • Thermostat and housing
    • Jacket water pump, belt driven, centrifugal
    • Auxiliary sea water pump, gear driven (heat exchanger and keel cooled engines only)
    • Radiator, engine mounted (includes guard, blower fan, fan drive, fan guard)
    • Expansion tank (heat exchanger engines only)
    • Engine mounted heat exchanger, removable tube bundle (for sea water) (heat exchanger engines only)
    • Engine oil cooler
    • Auxiliary sea water lines
    • Keel cooling (includes pipe thread flange kit)
  • Exhaust System
    • Manifold & Turbocharger, watercooled
    • 152 mm (6 in) round flanged outlet
    • Elbow, dry, 152 mm (6 in)
  • Flywheels & Flywheel Housings
    • Flywheel, SAE No. 1, 113 teeth
    • Flywheel housing, SAE No. 1
  • Fuel System
    • Fuel filter, Front service
    • Fuel transfer pump
    • Fuel priming pump
  • Generators
    • 12 lead, reconnectable
    • 3 phase Brushless
    • Separately excited from auxiliary winding to provide 300% short circuit current up to 10 seconds
    • 2/3 Pitch
    • Broad voltage band
    • IP23 Water protection
    • Solid state voltage regulator with integral voltage adjustment
    • Class H insulation
    • Generator temperature rise exceeds marine society requirements for Class H insulation
    • 105 C @ 50 C ambient - prime
    • 85 C @ 50 C ambient - prime Connection poles
  • Instrumentation
    • Instrument panel
    • Electric service meter
    • Start/stop switch
    • Emergency stop button
    • Maintenance due light
    • Diagnostic light
    • Warning light
    • Maintenance clear switch
    • 15A breaker
  • Lube System
    • Crankcase breather
    • Oil filter, spin-on, RH Service
    • Oil filler, in valve cover
    • Oil level gauge, LH service
    • Oil pan
    • Oil pan drain, LH service
    • Engine oil pump (gear driven)
  • Mounting System
    • Skiddable base frame
    • Front support
    • Anti vibration isolators between base and engine-generator
  • Protection System
    • Overspeed shutoff - electronic
  • General
    • Torsional vibration damper and guard
    • Lifting eyes
    • Protective lifting covers
    • Literature
    • Battery disconnect switch
    • Engine Wiring
    • Plastic wrap packaging
    • NOTE: Engines for keel cooling do NOT include keel cooler.

Optional Equipment:

  • Air Inlet System
    • Air Cleaner Rain Cap
  • Control System
    • Load sharing attachment
  • Cooling System
    • Coolant recovery tank
    • Coolant level sensor
    • Coolant Flange Kit
  • Exhaust System
    • Elbows
    • Pipe
    • Flexible fittings
    • Flange
    • Rain caps
    • Mufflers
    • Shields
  • Fuel System
    • Fuel cooler
    • Flexible fuel lines
    • Fuel temperature sensor
    • Fuel and oil shielding
  • Generators And Generator Attachments
    • Extension Terminal Box
    • Engine and Generator Certification:
  • Instrumentation
    • Magnetic Pickup
  • Lube System
    • Sump Pumps, Manual
    • Duplex Oil Filters
  • Power Take-offs
    • Crankshaft pulley
  • Starting System
    • Air pressure regulator
    • Air silencer

Take The Virtual Product Tour To Explore The Features And Benefits of the C9 Generator Set Package

See how C9 compares against frequently compared products

C9 Marine Generator Sets

Bore
4.41 in
Stroke
5.87 in
Selected Model

C1.5 Marine Generator Sets

Configuration
Inline 3, 4-Stroke Cycle diesel
Bore
3.31 in
Stroke
3.5 in
View Full Specs

C4.4 (Electronic) Marine Generator Sets

Configuration
In-line 4, 4-stroke-cycle diesel
Bore
4.13 in
Stroke
5 in
View Full Specs

Compare with other Cat Models

Compare Now

Media Gallery

Check out our current offers

View Specials
Translate »