3412C Generator Set
Diesel Generator Sets
Diesel Generator Sets (178)
-
CM43C (Inline)
-
CM46DF (V-Type)
-
CM25E Generator Set
-
CM32C (V-Type) Generator Set
-
CM32C (Inline) Generator Set
-
CM32E
-
C15 Tier 4 Interim
-
C27 Tier 4 Interim
-
3516E High Voltage Generator Set
-
3516B (50 Hz) with Upgradeable Package
-
C32 Generator Set with Upgradeable Packaging
-
C280-16 Generator Set (Medium Speed)
-
3616 Generator Set (Medium Speed)
-
C280-12 Generator Set (Medium Speed)
-
3612 Generator Set (Medium Speed)
-
3616 Generator Set (Medium Speed)
-
3612 Generator Set (Medium Speed)
-
3608 Generator Set (Medium Speed)
-
3608 Generator Set (Medium Speed)
-
C280-8 Generator Set (Medium Speed)
-
C280-6 Generator Set (Medium Speed)
-
3606 Generator Set (Medium Speed)
-
C175-20
-
3606 Generator Set (Medium Speed)
-
C175-20
-
C175-16 Tier 4 Final
-
C175-16 Generator Set
-
C175-16 Generator Set
-
3516E Low Voltage Generator Set
-
3516E Low Voltage Generator Set
-
3516E Generator Set
-
3516E Generator Set
-
3516E Low Voltage Generator Set
-
3516C Tier 4 Final
-
3516C Generator Set
-
3516C Generator Set
-
3516C (50 Hz) with Upgradeable Package
-
3516C Generator Set
-
3516B (50 Hz) Generator Set
-
3516B (60 Hz) with Upgradeable Package
-
3516B Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516 Diesel Generator Set
-
3516B (50 Hz) India Market Only
-
3516 Diesel Generator Set
-
3516B Generator Set
-
3512C Generator Set
-
3512C Generator Set
-
3516 Diesel Generator Set
-
3516 Diesel Generator Set
-
3512B Diesel Generator Set
-
3512B Diesel Generator Set
-
3512B (50 Hz) Generator Set
-
3512B Diesel Generator Set
-
3512B (50 Hz) India Market Only
-
3512 Generator Set
-
3512 Generator Set
-
3512 with Upgradeable Package
-
3512 Generator Set
-
DE1500 GC
-
C32 (60 Hz)
-
C32 Generator Set
-
D1250 GC
-
DE1250S GC
-
DE1250 GC (50 Hz)
-
DE1400 GC
-
C32 (50 Hz) India Market Only
-
DE1000S GC
-
D1000 GC
-
DE1100 GC
-
D800 GC
-
3412C Generator Set
-
3412C Generator Set
-
C27 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
DE600S GC Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
D600 GC (60 Hz) Generator Set
-
D550 GC (60 Hz) Generator Set
-
DE715 GC Generator Set
-
C18 (50 Hz) India Market Only
-
C18 Generator Set
-
DE550S GC (60 Hz) Generator Set
-
DE660 GC (50 Hz) Generator Set
-
C15 Generator Set
-
C15 Generator Set
-
DE605 GC (50 Hz) Generator Set
-
DE500S GC (60 Hz) Generator Set
-
D500 GC (60 Hz) Generator Set
-
DE450S GC (60 Hz) Generator Set
-
D450 GC (60 Hz) Generator Set
-
C15 Generator Set
-
DE550 GC (50 Hz) Generator Set
-
C15 (50 Hz) India Market Only
-
C15 (50 Hz) China Non Road
-
DE500 GC (50 Hz) Generator Set
-
D400 GC (60 Hz) Generator Set
-
C13 Generator Set
-
C13 Generator Set
-
C13 (50 Hz) China Non Road
-
C13 (50 Hz) India Market Only
-
DE450 GC (50 Hz) Generator Set
-
C13 Generator Set
-
DE400S GC Generator Set
-
DE400 GC Generator Set
-
C9 Generator Set
-
D350 GC (60 Hz) Generator Set
-
D250 GC (60 Hz) Generator Set
-
D300 GC (60 Hz) Generator Set
-
C9 Generator Set
-
DE350S GC Generator Set
-
C9 Generator Set
-
C7.1 Generator Set
-
C7.1 ACERT
-
D200 GC Generator Set
-
D175 GC Generator Set
-
DE220 GC (50 Hz) Generator Set
-
C7.1 ACERT
-
DE200 GC Generator Set (60 Hz)
-
DE218AE0 (60 Hz) Generator Set
-
DE169AE0 (60 Hz) Generator Set
-
DE218AE0 (50 Hz) Generator Set
-
DE165 GC Generator Set (60 Hz)
-
DE200 GC Generator Set (50 Hz)
-
DE150 GC Generator Set (60 Hz)
-
DE165 GC Generator Set (50 Hz)
-
D150 GC Generator Set
-
D125 GC Generator Set
-
DE169AE0 (50 Hz) Generator Set
-
C4.4 Generator Set
-
DE150 GC Generator Set (50 Hz)
-
C4.4 Generator Set
-
DE110 GC Generator Set (60 Hz)
-
DE125AE0 (60 Hz) Generator Set
-
C4.4 Generator Set
-
D100 GC Generator Set
-
DE125AE0 (50 Hz) Generator Set
-
DE110 GC Generator Set (50 Hz)
-
DE88 GC Generator Set (60 Hz)
-
DE100AE0 (60 Hz) Generator Set
-
DE100AE0 (50 Hz) Generator Set
-
DE88 GC Generator Set (50 Hz)
-
D80 GC Generator Set
-
DE65 GC Generator Set (60 Hz)
-
C3.3 Generator Set
-
D60 GC Generator Set
-
C4.4 Generator Set
-
DE75AE0 (60 Hz) Generator Set
-
C3.3 Generator Set
-
DE65 GC Generator Set (50 Hz)
-
DE75AE0 (50 Hz) Generator Set
-
D50 GC Generator Set
-
DE55 GC Generator Set (60 Hz)
-
DE56AE0 (60 Hz) Generator Set
-
DE50 GC Generator Set (60 Hz)
-
DE55 GC Generator Set (50 Hz)
-
D40 GC Generator Set
-
DE50 GC Generator Set (50 Hz)
-
DE56AE0 (50 Hz) Generator Set
-
DE33 GC Generator Set (60 Hz)
-
DE33 GC Generator Set (50 Hz)
-
C2.2 | D25 Generator Set
-
C2.2 | D20 Generator Set
-
C2.2 Generator Set
-
C2.2 | D30 Generator Set
-
C1.1 Generator Set
-
C1.5 Generator Set
-
C2.2 Generator Set
-
C1.5 Generator Set
-
C1.1 Generator Set
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
- Cat Generator Set Package
- Cat Diesel Engine
- SR500 Alternator
- EMCP 4 Control Panel
- Cooling System
- Certifications
- One Safe Source
- World Wide Product Support
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR500 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- EU Declaration of Conformity
- EU Declaration of Incorporation
- Eurasian Conformity (EAC)
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
World Wide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR500 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- EU Declaration of Conformity
- EU Declaration of Incorporation
- Eurasian Conformity (EAC)
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Engine Specifications
- Bore
- 5.4in
- Displacement
- 1648.86in3
- Stroke
- 6in
- Aspiration
- TA
- Fuel System
- Pump and Lines
- Engine Model
- 3412C TA, V-12, 4-Stroke Water-Cooled Diesel
- Compression Ratio
- 13:01
- Governor Type
- ADEM™ A5
- Fuel System
- 6in
- Aspiration
- TA
- Fuel System
- Pump and Lines
- Bore
- 5.4in
- Displacement
- 1648.86in³
- Stroke
- 6in
Generator Set Specifications
- Minimum Rating
- 680 kVA
- Maximum Rating
- 900 kVA
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Emissions/Fuel Strategy
- Low Fuel Consumption
- Duty Cycle
- Standby, Prime
Generator Set Dimensions
- Height - Maximum
- 75in
- Length - Maximum
- 162.4in
- Width - Maximum
- 78.3in
- Width - Minimum
- 75in
- Dry Weight - Genset (minimum)
- 12039lb
- Dry Weight - Genset (maximum)
- 13030lb
Standard/Optional Features
Standard Equipment:
-
- Air Inlet System
-
- Air cleaner, single element canister type with service indicator
-
- Control Panel
-
- EMCP 4.2B
- Customer data link (Modbus RTU)
- 2 Programmable relay outputs (Form C)
- Features include:
- Voltage adjust
- Failure to start (overcrank)
- Volts (L-L & L-N)
- Reverse power (kW) (32)
- Accessory module data link
- Over/under voltage (27 / 59)
- Speed adjust
- Low coolant temperature
- Oil pressure (psi, kPa or bar)
- Environmental sealed front face
- Generator temperature monitoring module
- DC volts
- Serial annunciator module data link
- Reverse reactive power (kVAr) (32RV)
- Amps (per phase & average)
- High coolant temperature
- 24 Volt DC operation
- Communications
- Power factor (per phase & average)
- Compatible with the following optional modules:
- Low coolant level
- Text alarm/event descriptions
- Digital I/O module
- 6 programmable digital inputs
- Low oil pressure
- Remote Serial annunciator
- Engine cycle crank
- Local annunciator
- Digital indication for:
- Over/under frequency (81 o/u)
- Generator phase sequence
- Emergency stop
- kVAr (per phase, average & percent)
- Run/auto/ stop/control
- Operating hours
- kVA (per phase, average & percent)
- Warning/shutdown with common LED indication of shutdowns for:
- Emergency stop pushbutton
- Frequency (Hz)
- coolant temperature
- Overspeed
- 4 programmable relay outputs (Form A)
- kW-hr (total)
- 2 Programmable digital outputs
- Remote CAN annunciator
- Overcurrent (50 / 51)
- kW (per phase, average & percent)
- RPM
- Programmable protective relaying functions:
-
- Cooling System
-
- Radiator with guard (Sized for 50 degrees C)
- Coolant level shutdown
- Coolant drain line with valve, piped to edge of base
- Fan and belt guards
- Caterpillar extended life coolant
-
- Exhaust System
-
- Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
-
- Fuel System
-
- Primary and Secondary fuel filters
- Fuel priming pump
- Flexible fuel lines terminated on base
- Water seperator
-
- Generator And Attachments
-
- 2:1 Volts/Hz
- Busbar termination
- 3-phase sensing
- Class H insulation
- Reactive droop
- VR6 voltage regulator
- SR4B self excited
- 12 Leads
- Class F temperature rise
-
- Governing System
-
- Cat electronic governor
-
- Lube System
-
- Oil drain line with valve, piped to edge of base
- Lubricating oil
- Oil filter
- Fumes disposal, piped to front of radiator
-
- Mounting System
-
- Base, formed steel with linear vibration isolators between base and engine-generator
-
- Starting / Charging System
-
- 45 amp Charging alternator
- Battery with rack, cables
- Fuel shutoff solenoid
- 24 volt starting motor
Optional Equipment:
-
- Air Inlet System
-
- Heavy duty air cleaners
- Dual element air cleaners
- Open element air cleaners
-
- Circuit Breakers
-
- 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
- 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
-
- Control Panel
-
- Generator temperature monitoring package
- EMCP 4.4
- First local annunicators
- Vandal proof panel door
- Remote custom annunicator
- EMCP 4.3
- Local discrete I/O package
- Common alarm/shutdown relay
- Ground fault relay
- Generator running VFC
-
- Cooling System
-
- Radiator duct flange
- Jacket water heaters
-
- European Certifications
-
- Eurasian Conformity (EAC) mark
-
- Exhaust System
-
- Through wall installation kit
- Mufflers
- Manifold and turbocharger guards
- Elbow kit
-
- Generator And Attachments
-
- Permanent magnet excitation (PMG)
- Space heater
- Digital voltage regulator
- Oversize and premium generators
-
- Lube System
-
- Manual sump pump
-
- Mounting System
-
- Fuel tank base (1200 ltr)
-
- Special Tests / Reports
-
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
-
- Starting / Charging
-
- Oversize batteries
- Battery chargers
- Battery disconnect switch
- Heavy duty starting system
-
- Governing System
-
- Electronic load share