C18 Generator Set

Diesel Generator Sets
Diesel Generator Sets (172)

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Design Criteria
The generator set meets NFPA 110 loading requirement and meets ISO 8528-5 transient response.
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
GCCP 1.3 Control Panel
The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further...
Single-Source Supplier
Fully prototype tested with certified torsional vibration analysis available
Worldwide Product Support
Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S�ۢO�ۢS��� program cost effectively detects internal engine component condition, even the presence of ...
Seismic Certification
  • Seismic Certification available.
  • Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength.
  • IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer
  • Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007, CBC 2010
UL2200 Listed; CSA 22.2; Certification of Compliance – IBC Seismic; Dual IBC & HCAI
Certfications
Design Criteria
The generator set meets NFPA 110 loading requirement and meets ISO 8528-5 transient response.
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
GCCP 1.3 Control Panel
The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.
Single-Source Supplier
Fully prototype tested with certified torsional vibration analysis available
Worldwide Product Support
Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S�ۢO�ۢS��� program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products
Seismic Certification
  • Seismic Certification available.
  • Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength.
  • IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer
  • Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007, CBC 2010
  • Pre-approved by OSHPD and carries an OSP-0321-10 for use in healthcare projects in California
UL2200 Listed; CSA 22.2; Certification of Compliance – IBC Seismic; Dual IBC & HCAI
Certfications

Generator Set Specifications

Minimum Rating
706 kVA
Maximum Rating
850 kVA
Emissions/Fuel Strategy
Low Fuel
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.71in
Stroke
7.2in
Displacement
1106.4in³
Compression Ratio
14.5:1
Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
162.4in
Width - Maximum
78.3in
Height - Maximum
75in

Standard/Optional Features

Standard Equipment:

  • Air Inlet System
    • Single element air cleaner
    • Turbocharger
    • Aftercooler core
    • Light duty air cleaner
  • Control System
    • GCCP 1.3
  • Cooling
    • Coolant drain line with valve
    • Radiator and cooling fan with guard
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
  • Exhaust System
    • Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard 8 hour open set integral fuel tank
  • Generator And Attachments
    • LC frame generator - IP23 Protection
    • Matched to the performance and output characteristics of Cat engines
    • Segregated low voltage (AC/DC) wiring panel
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    • Integrated voltage regulator (IVR)
    • Power center, IP22
    • Integrated voltage regulator (IVR)
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Lubricating oil
    • Oil drain lines with valves
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator.
  • Starting/charging
    • 24 Volt battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Air Inlet System
    • Dual element air cleaner
  • Circuit Breakers
    • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
    • Circuit breaker (IEC) Auxiliary contacts
    • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
    • Padlockable circuit breaker device
    • Shunt trip for IEC breaker
    • Power terminal strip
    • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
    • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • Control System
    • Local alarm horn
    • Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
    • GCCP 1.4
    • Remote annunciator module
    • Oil temperature displays
    • Local alarm modules
  • Cooling System
    • Radiator transition flange
    • Low coolant temperature alarm
  • Enclosures
    • Sound attenuated enclosures (to be available soon)
  • Exhaust System
    • 8 and 10 inch elbow kits
    • 10, 25, 35 dB end in / end out mufflers
    • Engine mounted muffler
    • 8 and 10 inch GP flanges
    • Manifold and turbocharger guards
  • Fuel System
    • Integral - Dual wall fuel tank base
    • Fuel transfer system
    • Manual fuel transfer pump
  • Generator And Attachments
    • Space heaters
    • A Frame CIP generator
    • LC frame CIP generator
    • A Frame oversize generator
    • Ingress protection
    • LC frame oversize generators
    • LC frame generator
    • Permanent magnet excitation (PMG)
  • Lube System
    • Manual sump pump
  • Starting And Charging
    • Jacket water heaters
    • 5 Amp Battery charger
    • Battery disconnect switch
    • Jacket water heaters

Take The Virtual Product Tour To Explore The Features And Benefits of the C18 Generator Set

See how C18 (50 Hz) compares against frequently compared products

C18 (50 Hz) Diesel Generator Sets

Engine Model
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Voltage
380 to 415 Volts
Maximum Rating
850 kVA
Selected Model

C1.1 (60 Hz) Diesel Generator Sets

Engine Model
C1.1, In-line 4, 4-cycle diesel
Voltage
110 to 480 Volts
Maximum Rating
8.8 ekW
View Full Specs

C1.1 (50 Hz) Diesel Generator Sets

Engine Model
C1.1, In-line 4 4-cycle diesel
Voltage
110 to 415 Volts
Maximum Rating
9.5 kVA
View Full Specs

Compare with other Cat Models

Compare Now

Media Gallery

Check out our current offers

View Specials
Translate »