C13 (50 Hz) China Non Road

Diesel Generator Sets
Diesel Generator Sets (181)

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Engine Specifications

Bore
5.12in
Displacement
762.80in³
Stroke
6.18in
Aspiration
Air to Air Aftercooled
Fuel System
MEUI
Engine Model
C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Compression Ratio
16.3:1
Governor Type
Adem™A4
Aspiration
Air to Air Aftercooled
Fuel System
MEUI
Bore
5.12in
Displacement
762.8in³
Stroke
6.18in
Fuel System
6.18in

Generator Set Specifications

Minimum Rating
350 kVA
Maximum Rating
450 kVA
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Emissions/Fuel Strategy
Low Fuel, R96/EUIIIa
Duty Cycle
Standby, Prime

Generator Set Dimensions

Height - Maximum
84in
Length - Maximum
186.7in
Width - Maximum
79.3in

Standard/Optional Features

Standard Equipment:

  • Air Inlet System
    • Air cleaner; light duty with disposable paper filter
    • Turbocharger
    • Aftercooler core
  • Control Panel
    • GCCP 1.3
  • Cooling System
    • Radiator and cooling fan with guard
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
  • Exhaust System
    • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Primary fuel filter w/integral water separator and secondary filter
    • Flexible fuel lines
    • Fuel priming pump
    • Engine fuel transfer pump
    • Fuel coolers with single wall integral 8-hour fuel tank
  • Generator And Attachments
    • Integrated voltage regulator (IVR)
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    • A Frame generator - IP21 Protection
    • Power center, IP22
    • Optional LC Frame generator - IP23 Protection
    • Segregated low voltage (AC/DC) wiring panel
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Lubricating oil
    • Oil drain valves
  • Packaged Generator Set
    • Service indicator
    • Disposable air filter
    • Coolant level sight gauge
    • Low coolant level sensor
    • Coolant drain line with valve
    • Radiator package mounted
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines.
  • Starting / Charging System
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • European Certificates
    • Global Certification for CIS
    • EU Certificate of Conformance (CE)
  • Air Inlet System
    • Single element air cleaner
    • Dual element air cleaner
  • Circuit Breakers
    • Padlockable circuit breaker device
    • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
    • 3 Pole (IEC-100% rated) Circuit breaker
    • 4 Pole (IEC-100% rated) Circuit breaker
    • Circuit breaker (IEC) Auxiliary contacts
    • Shunt trip for IEC circuit breaker
    • 4 Pole (IEC-100% rated) Circuit breaker - Motorised
  • Control Panels
    • Local alarm modules: Local annunciator
    • Volt free contacts
    • GCCP 1.4
    • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
    • Remote annunciator module
  • Cooling System
    • Radiator duct flange
    • Low coolant temperature alarm
    • Stone guards
  • Enclosures
    • High ambient sound attenuated enclosures
    • Sound attenuated enclosures
  • Exhaust System
    • 10, 25 and 35 dBA attenuation
    • Mufflers - End in/end out
    • 6 and 8 inch flange GP
    • Flexible 8 inch exhaust fittings
    • 6 and 8 inch elbow kit
  • Fuel System
    • Fuel transfer system controls
    • Integral dual wall fuel tank base
    • Manual fuel transfer pump
  • Generator And Attachments
    • Space heaters
    • LC frame generator
    • LC frame oversize generator
    • LC CIP generator
    • A Frame oversize generator
    • A Frame CIP generator
    • Permanent magnet excitation (PMG) generator
    • Ingress protection
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base
  • Starting / Charging System
    • 5 Amp single Battery charger
    • Jacket water heater
    • Battery disconnect switch

Take The Virtual Product Tour To Explore The Features And Benefits of the C13 (50 Hz) China Non Road

See how C13 (50 Hz) China Non Road compares against frequently compared products

C13 (50 Hz) China Non Road Diesel Generator Sets

Engine Model
C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Voltage
380 to 415 Volts
Maximum Rating
450 kVA
Selected Model

C1.1 (50 Hz) Diesel Generator Sets

Engine Model
C1.1, In-line 4 4-cycle diesel
Voltage
110 to 415 Volts
Maximum Rating
9.5 kVA
View Full Specs

C2.2 (50 Hz) Diesel Generator Sets

Engine Model
Cat® C2.2, In-line 4, 4-cycle diesel
Voltage
110 to 415 Volts
Maximum Rating
22.0 kVA
View Full Specs

Compare with other Cat Models

Compare Now

Media Gallery

Check out our current offers

View Specials
Translate »