Cat XLM Switchgear
Electric Power
Electric Power (218)
-
UPS Generator Set Start Module
-
G80LG6 Gas Generator Set
-
G60LG2 Gas Generator Set
-
G70LG2 Gas Generator Set
-
G45LG2 Gas Generator Set
-
G50LG2 Gas Generator Set
-
G300LG6 Gas Generator Set
-
G35LG2 Gas Generator Set
-
G40LG2 Gas Generator Set
-
GEUG16-1 Gas Generator Set
-
G275LG6 Gas Generator Set
-
G200LG6 Gas Generator Set
-
G230LG6 Gas Generator Set
-
G175LG6 Gas Generator Set
-
G150LG6 Gas Generator Set
-
G130LG4 Gas Generator Set
-
G100LG4 Gas Generator Set
-
G25LTA2 Gas Generator Set
-
GES550-1
-
ATC-100 CONTROLLER
-
GES450-5
-
Engine Generator Integrated Switchgear
-
Photovoltaic Module PVT
-
Heavy Duty ESS 48V DC
-
Photovoltaic (PV) Module PVT115
-
General Service ESS 48V DC
-
XQ230
-
XG400
-
XQ2000
-
XQE30
-
XQE60
-
XQ2000
-
XQE20
-
XQ500
-
XQ800
-
XQ200
-
XQ100
-
XQ300
-
20-2000 kVA
-
300kW
-
550kW
-
400kW
-
DG450-2 (Single-phase)
-
DG275-2 (Single-phase)
-
DG350-2 (Single-phase)
-
DG400-2 (Single-phase)
-
DG230-2 (Single phase)
-
DG250-2 (Single-phase)
-
G3306 Gas Generator Set
-
CG132-8 Gas Generator Set
-
CG260-16 Gas Generator Set
-
CG132-12 Gas Generator Set
-
CG260 Gas Generator Set
-
Gas Generator G3516E
-
Gas Generator CG132
-
G3508A
-
G3512A Generator Set
-
DG300-2 (Single-phase)
-
C27 Tier 4 Interim
-
C6.6 Generator Set
-
C15 Tier 4 Interim
-
D550 GC (60 Hz) Generator Set
-
3512B-HD (CTL) Generator Set
-
3516E High Voltage Generator Set
-
3516C Generator Set
-
3512B Diesel Generator Set
-
C32 (60 Hz) with Upgradeable Packaging
-
C13 Generator Set
-
C32 Generator Set with Upgradeable Packaging
-
C32 Generator Set with Upgradeable Packaging
-
3516B (50 Hz) with Upgradeable Package
-
GEP218-3
-
GEP100-1
-
GEP125-1
-
GEP169-1
-
MX250 Microprocessor Controller
-
MX350 Controller
-
CTX Series Automatic Transfer Switch
-
MX150 Microprocessor Controller
-
CTS Series Automatic Transfer Switch
-
CTSM and CTGM Series Manual Transfer Switches
-
CTE Series Automatic Transfer Switch
-
CTG Series Automatic Transfer Switch
-
CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch
-
ATC-300+ CONTROLLER
-
ATC-800 CONTROLLER
-
ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch
-
ATC Service Entrance Rated MCCB & Power Breaker Based ATS
-
ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
-
ATC Power Breaker & Case Switch Automatic Transfer Switch
-
ATC Contactor Based Bypass Isolation Automatic Transfer Switch
-
ATC Contactor-Based Automatic Transfer Switch
-
Cat Customizable Switchgear and Controls
-
Cat Switchgear
-
Cat EGP Switchgear
-
Cat XLM Switchgear
-
EMCP 4.4 Master Control Panel
-
Emergency Transfer Load manager
-
Engine Paralleling and Integration Control (EPIC)
-
Photovoltaic Module PVC
-
Photovoltaic Module PVC
-
Photovoltaic Module PVC
-
CAT® BDP 250 ENERGY STORAGE INVERTER
-
Temporary Connection Boxes
-
XGC1900
-
XQC1200
-
XQC1600
-
XQP1100 Rental Generator Set
-
XQ1475G
-
XQP500
-
XQ570
-
XQ425
-
XQP275
-
XQP300
-
XQP150
-
XQ230 Rental Power
-
XQ125 Rental Power
-
XG135 – Natural Gas
-
XQP60
-
XQP100
-
XQ35
-
XQ60
-
CG170-20 Gas Generator Set
-
CG170-12 Gas Generator Set
-
CG170 Gas Generator Set
-
G3520H Gas Generator
-
G3520E Gas Generator Set
-
Gas Generator G3516H
-
G3520C Gas Generator
-
Gas Generator G3516B
-
G3516C Gas Generator Set
-
Gas Generator G3516A
-
Gas Generator G3512H
-
G3512E Gas Generator Set
-
G3512 1000kW Gas Generator Set
-
G3412 Gas Generator Set
-
G3512 750kW Gas Generator Set
-
G3406 Gas Generator Set
-
DG350-2 (Single-phase)
-
DG400-2 (Three phase)
-
DG450-2 (Single-phase)
-
DG275-2 (3 phase)
-
DG300-2 (3 phase)
-
DG230-2 (3 phase)
-
DG250-2 (3 phase)
-
DG200-2 (3 phase)
-
DG200-2S (Single-phase)
-
DG175-2 (Single-phase)
-
DG175-2 (3 phase)
-
DG150-2 (3 Phase)
-
DG100-2 (3 Phase)
-
DG125-2 (3 Phase)
-
DG80-2 (3 Phase)
-
DG100-2S (Single Phase)
-
DG60-2 (3 Phase)
-
DG80-2 (Single Phase)
-
DG50-2 (3 Phase)
-
DG60-2 (Single Phase)
-
DG50-2 (Single Phase)
-
CM20C Generator Set
-
3608 Generator Set (Medium Speed)
-
3612 Generator Set (Medium Speed)
-
3616 Generator Set (Medium Speed)
-
3606 Generator Set (Medium Speed)
-
C175-16 Tier 4 Final
-
C175-20
-
3516E Low Voltage Generator Set
-
C175-16 Generator Set
-
3516C Tier 4 Final
-
3516C Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516B (50 Hz) Generator Set
-
3516B Generator Set
-
3516B Generator Set
-
3516 Diesel Generator Set
-
3516 Diesel Generator Set
-
3516 Diesel Generator Set
-
3512C Generator Set
-
3512B Diesel Generator Set
-
3512C Generator Set
-
3512 Generator Set
-
C32 (60 Hz)
-
3412C Generator Set
-
C27 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C18 Generator Set
-
C15 Generator Set
-
C15 Generator Set
-
C13 Generator Set
-
C13 Generator Set
-
C9 Generator Set
-
C9 Generator Set
-
C7.1 Generator Set
-
C7.1 ACERT
-
C4.4 Generator Set
-
C7.1 ACERT
-
C4.4 Generator Set
-
C4.4 Generator Set
-
C3.3 Generator Set
-
C4.4 Generator Set
-
C1.1 Generator Set
-
C1.5 Generator Set
-
XQ 500
-
XQ 800
-
XQ 200
-
XQ1500
-
XQ1000
-
XQ400
-
XQ350
-
XQ300
-
XQ230
-
APS150
-
XQ100
-
XQ30
-
XQ2000
Overview
The Emergency Transfer and Load management (XLM) product supports transfer between the utility source and generator bus and allows for sustained parallel operation with the utility for load management applications.
XLM Switchgear
- High Speed Supervisory Network
- Automatic Start/Stop
- Automatic “Dead Bus” Coordination
- Automatic Power Factor Control when in Parallel with Utility Power
- Programmable Load Shed / Load Add Functions
- Networked Engine Communications
- Generator & Utility Protection
XLM Switchgear
- High Speed Supervisory Network
- Automatic Start/Stop
- Automatic “Dead Bus” Coordination
- Automatic Power Factor Control when in Parallel with Utility Power
- Programmable Load Shed / Load Add Functions
- Networked Engine Communications
- Generator & Utility Protection
- Engine Tuning
- Mode Selection
- Selectable Auto/ Manual Control
- Password Protection for Protective Settings and Setup
- Load/No Load Test
- Touch Screen (HMI) Display
- NFPA 99/110 Compliant Alarm
- Annunciation with Audible Horn
- Engine Control mimic Screen with gauges for RPM, DC Battery Voltage, Oil Pressure, Engine Coolant temperature, Engine Hours, Number of starts
Technical Summary
- Configuration
- Traditional customizable PLC based floor standing switchgear capable of controlling and monitoring multiple utilities, generators, and loads
- Modes of Operation
- Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
- Application
- LV and MV ( 208V - 38 kV
- Configuration
- Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
- Modes of Operation
- Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
- Application
- LV and MV ( 208V - 38 kV
Environmental Parameters
- Operating Temperature
- 0 degrees to 50 degrees C
- Storage Temperature
- -20 degrees C to +60 degrees C
- Medium Voltage Standards
- NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110
- Certifications
- IBS, CBC, UBC & OSHPD Certified
- Control Panel Enclosure
- NEMA 1 or NEMA 3R, Freestanding Construction
- Low Voltage Standards
- NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70
- Operating Temperature
- 0 degrees to 50 degrees C
- Storage Temperature
- -20 degrees C to +60 degrees C
- Medium Voltage Standards
- NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110
Generator Protective Devices
- ANSI Protective Devices
- 15/25, 27/59, 81 O/U, 32, 40, 50, 51
Utility Protective Devices
- ANSI Protective Devices
- 15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86
Standard/Optional Features
Standard Equipment:
-
- Generator Demand Priority Control
-
- Automatically match the on-line generator capacity to the loads, and avoid unnecessary operation of generator sets.
Optional Equipment:
-
- Data Table Interface
-
- Accommodates interface with a building management system for monitoring all system parameters via Modbus RTU or TCP
-
- Supplemental Hardware Synchronization Check Relay (ansi 25 Device)
-
- Provides additional discrete synchronization protection
-
- Remote Power Monitoring System
-
- To monitor breaker status, alarms, metering and other operating parameters